CareUcar Battery Analyzer User Manual page 18

Table of Contents

Advertisement

www.CareUcar.com
12.
Email: sales02@careucar.com MSN: careucar@hotmail.com
Skype: careucar
For less than 5 seconds, the results of the testing will be displayed on
the LCD screen. (Fig. 14)
Interpretations of the above results:
1.
RESULTS:
A very straight forward display of the final results basing on the
evaluation of the tested condition. 'Good' indicates the battery in
good condition. 'Replace' indicates that the battery needs to be
replaced. If not, the battery will fail anytime without any warning.
2.
Voltage :
12.46V
This indicates the tested battery voltage (12.46V). It depends on
the state of charge on the battery:
100% fully charged
90% charged
75% charged
3.
CCA (Cold Cranking Amps):
CCA ratings has been used here, therefore the tested result is in
406 CCA. If other rating (DIN or JIS, or IEC, or EN) were selected,
it will base on the respective rating to calculate and show the
results in that selected rating.
4.
Int. R (Internal Resistance):
In normal condition, the internal resistance should fall between
2.0 mΩ ~ 15.0 mΩ. As a matter of fact, the higher the battery
CCA readings obtained the lower the internal resistance should
be.
5.
LIFE:
50 %
This is an indication of the battery life expectancy in percentage. If
the life falls below 45 %, the RESULT will display "Replace" and it
is time to change to a new battery.
Figure 14
Good
-
13.20V
-
12.90V
-
12.45V
406 CCA
6.72mΩ
Yahoo: careucar@ymail.com
Battery Analyzer Series
-
-
18 -

Advertisement

Table of Contents
loading

Table of Contents