Ex Zone 1 (Category 2 Equipment); Iecex; Class I, Division 1 / Class I, Zone 1 - Sartorius TopMix2.Touch TM02-X Operating Instructions Manual

Paint-mixing terminal/control panel for potentially explosive areas
Hide thumbs Also See for TopMix2.Touch TM02-X:
Table of Contents

Advertisement

Ex Zone 1 (Category 2 Equipment)

– In accordance with Directive 94/9/EC, the TopMix terminal (TM02-X) is a category 2 device, suitable for use
in Zone 1 potentially explosive areas.
EC Type Examination Certificates: DEKRA 12ATEX0246 X marking: II 2G Ex ib mb IIB T4 Gb
– The ex-link converter (YCO12-Z) is an associated electrical equipment for use ouside the potentially explo-
sive are with the following marking II (2)G [Ex ib Gb]IIB as per EC Type Examination Certificate No DEKRA
12ATEX0246 X
It may only be connected to supply voltages of 90 V to 264 V at a frequency of 48 – 62 Hz.

IECEx

The TopMix terminal, the keyboard and the ex-link converter are also IECEx certified by DEKRA
(see Certificate IECEx DEK 12.0072X in the appendix).

Class I, Division 1 / Class I, Zone 1

The TopMix terminal, the keyboard and the ex-link converter are certified by FM Approvals for use in hazardous
locations in Canada and in the USA (see Certificates Compliance in the appendix).
If the device is used in potentially explosive areas, the relevant national electrical codes and safety regulations
must be observed. Ask the dealer or Sartorius Service Center about the guidelines that apply in their country.
The following points must be followed:
The TopMix should only be opened by trained personnel with the power disconnected.
The device is intended to be installed exclusively in locations that offer sufficient protection against the
penetration of solid foreign bodies or water. The safety of the equipment is compromised by foreign bodies
and water.
The terminal/control panel must be protected against damage and direct or indirect penetration of water and
foreign bodies (< 1 mm diameter).
Avoid generating static electricity on the glass panel of the touch screen and plastic casing.
The equipotential bonding conductor of the device must be connected properly, in accordance with the
commonly accepted technical standards.
Only clean the device as stipulated in the cleaning instructions.
Take care that the glass panel of the touch screen is not damaged (e.g. by falling objects, impacts or extreme
pressure).
If the glass panel is damaged, disconnect the device from the power supply immediately.
The surface of the touch screen should not be touched with pointed, sharp, hard, or rough objects. You should
only use the touch pen provided or your finger tip. Do not use parts of clothing (e.g. sleeves) or sponges for
cleaning because these can scratch the surface (e.g. due to rivets, buttons in the sleeve, or sand in the sponge).
The device must be protected from unnecessarily extreme temperatures, corrosive chemical vapors, moisture,
shocks, and vibrations. Note the connection data (see EC Type Examination Certificate of the device and/or the
safety instructions, drawing no. 36942-750-16). If a non-intrinsically safe scale is connected, then you cannot
connect an intrinsically safe scale later on.
Safety Precautions