Download Print this page

Front Panel Description - Rane DC 22 Operator's Manual

Rane stereo compressor operators manual

Advertisement

Front Panel Description

INPUT LEVEL indicators: With signal applied, the +4 dBu
LED may light occasionally. If the OL (overload) LED flashes,
turn the output level down on the previous device.
GATE THRESHOLD control sets the point at which the Input
signal level causes the Gate to become active.
_____________________________________________
COMPRESSOR THRESHOLD control sets the point at
which the Input signal level causes the Compressor to become
active. See Figure 1 on page Manual-4.
COMPRESSOR RATIO control: Once the Threshold is
exceeded, the Ratio of input change to output change is deter-
mined by this control. The compressor has no effect when set
at 1:1. But at 10:1, it takes a 10 dB input signal increase above
the Threshold to produce a 1 dB increase in Output Gain. See
Figure 2 on page Manual-4.
GAIN REDUCTION LEDs show the amount of average signal
reduction in dB. This aids in setting the THRESHOLD and
RATIO controls by showing how much compression is occur-
ing.
_____________________________________________
BYPASS switch compares the compressed and non-compressed
signal. There is one for each channel. The INPUT LEVEL
indicators remain active regardless of switch position.
GATE
OUTPUT LEVEL control increases or decreases the output
-50
gain of each Channel by 15 dB. In the center detent, gain will
-60
-40
-20
be unity.
-70
-30
-30
LINK switch activates both Compressors when either channel's
-80
-20
signal exceeds the set Threshold, preserving stereo imaging.
dBu
Switch this ON when using stereo material. The channel 1
THRESHOLD
controls become the Master when this switch is active, render-
ing the channel 2 controls and indicators dead.
_____________________________________________
Channel 2 controls duplicate the controls in channel 1. These
are not active if the LINK switch is engaged.
INPUT
LINK
+4 dBu
MASTER
SLAVE
Manual-
INPUT
1
-60
-70
+4 dBu
OL
-80
LEVEL
THRESHOLD
COMPRESSOR
-10
2
0
1.7
10
1.2
-40
20
1
dBu
:1
THRESHOLD
RATIO
GATE
-50
2
-60
-40
-70
-30
-30
OL
-80
-20
dBu
LEVEL
THRESHOLD
GATE
-50
-40
-20
-30
-30
-20
-40
dBu
THRESHOLD
3
3
6
10
12
24
GAIN
REDUCTION
BYPASS
COMPRESSOR
3
-10
2
-20
0
1.7
3
6
10
1.2
10
12
24
-40
20
1
dBu
:1
GAIN
THRESHOLD
RATIO
REDUCTION
Power switch is your basic, straightforward power switch. When
the switch is depressed and the yellow LED is lit, the DC 22
is ready to go.
INPUT
+4 dBu
COMPRESSOR
-10
2
0
1.7
3
10
1.2
10
20
1
dBu
:1
RATIO
OUTPUT
0
-6
6
-12
12
-15
15
dB
LEVEL
OUTPUT
0
-6
6
-12
12
-15
15
dB
BYPASS
LEVEL
GATE
-50
1
-60
-40
-70
-30
OL
-80
-20
dBu
LEVEL
THRESHOLD
OUTPUT
3
-6
6
-12
12
24
-15
GAIN
REDUCTION
BYPASS
LINK
MASTER
SLAVE
DC 22
DYNAMIC
CONTROLLER
POWER
-20
-30
-4
T
0
6
12
15
dB
LEVEL
INP
2
+4 dBu
LEV

Advertisement

loading