HEATILATOR ECO-CHOICE
B. Clearances to Combustibles (UL and ULC)
A
B
Straight Back Against Wall
A
Back Wall to Appliance
B
Side Wall to Appliance
Corner Installation
C
Walls to Appliance
Installations with
3 to 3 inch Top Vent Adapter
D
F
E
Vertical Installation
D
Back Wall to Adapter
E
Side Wall to Appliance
F
Back Wall to Appliance
Corner Installation
G
Walls to Appliance
Installations with
3 to 6 inch Offset Adapter
Vertical Installation
D
Back Wall to Adapter
E
Side Wall to Appliance
F
Back Wall to Appliance
Corner Installation
G
Walls to Appliance
NOTE:
• Illustrations refl ect typical installations and are FOR DESIGN
PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design
preference.
10
C
C
Inches
Millimeters
2
51
14
356
Inches
Millimeters
2
51
G
G
Inches
Millimeters
1
25
14
356
6-1/4
159
Inches
Millimeters
2
51
Inches
Millimeters
3
76
14
356
10-3/4
274
Inches
Millimeters
2
51
7058-205A
C. Hearth Pad Requirements (UL and ULC)
Use a non-combustible fl oor protector, extending beneath
appliance and to the front, sides and rear as indicated. Mea-
sure front distance "M" from the surface of the glass door.
K
Hearth Pad Requirements
K
Sides
L*
Back
M
Front
*L Exception for Horizontal Installations:
USA INSTALLATIONS: A non-combustible fl oor protec-
tion is recommended extending beneath the fl ue pipe when
installed with horizontal venting or under the Top Vent
Adapter with vertical installation.
CANADA INSTALLATIONS: A non-combustible fl oor pro-
tection extending beneath the fl ue pipe is required with hor-
izontal venting or under the Top Vent Adapter with vertical
installation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
WARNING
Fire Risk
Comply with all minimum clearances to combustibles as
specifi ed.
Failure to comply may cause house fi re.
L*
K
M
Inches
Millimeters
2
51
2
51
6
152
6/16/2014