Performing The Required Tests - Polaroid Miniportrait 204 Repair Manual

Hide thumbs Also See for Miniportrait 204:
Table of Contents

Advertisement

Repair Manual
To exit the Diagnostic Mode at any
time, press the Aiming Button (P) which
performs the exit function when in the
Diagnostic Mode. Or, select Exit from
the menu.

(2) Performing the required tests

Test:
Run In
Aim Lamp
Beeper
Shutters
Function performed:
Simulates normal camera operation - LCD panel
displays RUN-IN WITH COUNTER, shutters open
and close, and strobe fires (at both nominal and
maximum intensity). This continues until test mode
reaches 200 firings. Identifies the following:
LCD panel not illuminated, not readable, etc.
Shutters not functioning properly.
Strobe not firing or firing intermittently.
Aim Lamp blinks for one minute. This test can be
reactivated after a five minute cool-down period.
Identifies the following:
Aiming light not coming on, or not remaining on.
Aiming light not blinking.
Timer beeps continuously until test mode is exited.
Identifies the following:
Development timer not beeping at completion of
film development.
Sequentially opens and closes each shutter. This
continues until test mode is exited. Identifies the
following:
Shutter malfunctioning; not opening or closing,
sticking, etc.
25
Model 204/404 MiniPortrait Camera