Tone.
Enter a valid Arm/Disarm code, then

press
. If a valid Arm/Disarm code is entered,
the keypad will beep 6 times, indicating the panel

has been disarmed. The red Armed LED will go
out. If an incorrect Arm/Disarm Code is entered,
the keypad will sound a 1-second tone, indicating
incorrect entry. Press the
the code.
Disarming after an Alarm
(Alarm Memory)
The armed LED and the zone(s) that caused the
alarm will be be flashing. Disarm the panel. The
system is currently not detecting zone faults or
displaying system trouble.
The zone(s) that

caused the alarm will continue to flash. The
STATUS and
SYSTEM TRBL LEDs are out
indicating:

The system is displaying Alarm Memory.
Press the
key to clear Alarm Memory.
%\SDVVLQJ
Automatic Bypassing
Home/Away with Delay Zones
This zone type has the following operation de-
pending on whether an Exit/Entry Zone has been
violated during the Exit Delay time.
Home
Exit/Entry Zone is not violated
Zones selected as Home/Away with Delay
Zones will be bypassed automatically.
Away with Delay
key and re-enter
E xit/Entry Zone is violated
Zones selected as Home/Away with Delay
Zones will have a fixed 20-second entry
delay when violated before an Exit/Entry
Zone .
Full Setting the System with Automatic
Bypassing - Home/Away with Delay
Zones
From the Keypad
Press
Home/Away with Delay Zones that have
been automatically bypassed. Three min-
utes are allowed to walk through Exit/Entry
and Exit/Entry Follower Zones .
Using A Keyfob (GEM-KF)
All zones in the system can be armed
regardless of the state of the Exit/Entry
Zone when arming with a Keyfob and using
an AUX key programmed as Full Set.
Press
keys for 1.5s when leaving the
premises. All zones, including Home/Away
Zones are armed.

to return protection to


and press and hold the

Bypassing a zone
Press the
key, then the zone number to be
bypassed. While the panel is DISARMED, the
bypassed zone LED will flash slowly; indicating
the zone has been bypassed. While the panel is
ARMED, the bypassed zones will only be dis-
played if the Display Bypassed [21-3] option has

been selected.
Unbypassing a zone (Disarmed only)
Press the
key then the number of the
zone to be unbypassed.

Group Bypass
key to Bypass all Exit/Entry
Press the
Follower Zones [02] or Home/Away Zones
[01] (only if the system is programmed exclu-

sively for Home/Away with Delay zones ).
.
Using A Keyfob (GEM-KF)
Hold the
or
Bypass all Exit/Entry Follower Zones [02] or
Home/Away Zones [01] (only if the system is
programmed exclusively for Home/Away
with Delay zones ).
8VHU 3URJUDP 0RGH
To prevent the loss of the User 1 Code, the panel
or
default program includes User 1 Code Lockout
[96-2].
To change the User 1 Code from its default value
key on the Keyfob to
9