Pressure Adjustment - Titan WindMaster 2010 Operating Manual

Hydraulic tensioning pump
Table of Contents

Advertisement

By operating the tracer ⇑ on the hand remote control (Fig. 2) the hydraulic
pressure develops. Before starting, in each case, check the adjusted pressure
(chap. Pressure adjustment).
Fig. 2
By operating the tracer ⇓ on the remote control the pressure can be reduced
again.
If you are not using the pump motor, please switch it off (Main switch on Pos.0)
In order to avoid unnecessary wear and thermal loads on the device.
Do not touch the motor and parts near the motor after using it, since the
surfaces can be hot.

Pressure adjustment

The output / consumer pressure can be determined by adjusting the low pressure
at the pressure limiting valve. This adjusts the input pressure of the pressure
converter.
Turning clockwise (+) will increase the pressure, turning counterclockwise (-) will
reduce the pressure. The pressure converter operates with a conversion ratio of
1:13. This means, for example, that 10 bar of low pressure will generate an
output pressure of 130 bar.
The electric hydraulics pumps are factory-installed and adjusted to 1000 bar
initial pressure.
CAUTION: Disconnect all hoses and tensioners PRIOR to adjusting the
pressure.