Maintenance - Titan WindMaster 2010 Operating Manual

Hydraulic tensioning pump
Table of Contents

Advertisement

Maintenance

The first oil change and cleaning of the oil tank and the suction filter of the pump
should take place after approx. 50 service hours. All other oil changes depend on
the degree of contamination of the environment. The intervals must be
determined individually from case to case. It is usually sufficient to conduct this
maintenance work in an annual interval. However extreme conditions may
require much shorter intervals.
Cleaning the oil tank
It is only necessary to release the lid fastening screws on the unit and the entire
pump-motor unit can be removed. Then rinse out the oil tank with oil only. DO
NOT USE TEXTILES!!!
The suction filter of the pump must be examined and cleaned if necessary during
fluid changes.
High-pressure hoses
The high-pressure hoses must be examined to detect ageing (cracks, pores) and
must be replaced after 5 years at the latest.
Repair instructions
If repairs become necessary use original spare only. Use of non-Titan parts may
cause severe safety risk at worst and inferior performance at best.
Ensure extreme cleanliness during maintenance work on the pump to preserve
its function and service life.
The pressure converter must not be dismounted. All necessary repairs can only
®
®
be conducted by TITAN
or a authorized and certified TITAN
service technician.
®