Short Guidance - Titan WindMaster 2010 Operating Manual

Hydraulic tensioning pump
Table of Contents

Advertisement

Short guidance

The following steps must be taken before the first start:
Fill up hydraulic fluid (e.g. ISO VG 46) at the filler pipe if necessary until
the oil gauge is filled with oil
Connect the plug to a power source (Consider the electrical data)
Disconnect all hoses to the consumers
Close the manual shut-off valve (otherwise pressure-free circulation)
Adjust the working pressure at the pressure limiting valve
Build up the pressure by operating the tracer ⇑
Stop building up the pressure by releasing the tracer ⇑
Release the pressure by opening the manual shut-off valve or by
operating the tracer ⇓
CAUTION: ALWAYS CHECK THE MAX. ADJUSTED HYDRAULIC
PRESSURE FIRST WITHOUT THE HOSES OR TOOLS CONNECTED.
THE MAX. PERMISSIBLE HYDRAULIC PRESSURE OF THE SUPPLIED
HYDRAULIC GAUGE MUST NOT BE EXCEEDED.
TURN THE REGULATING KNOB COUNTERCLOCKWISE → REDUCES THE
PRESSURE
TURN THE REGULATING KNOB CLOCKWISE → INCREASES THE
PRESSURE
Always observe the hydraulic pressure gauge when applying pressure to the
pump.
Safety requires that you read very carefully and understand fully the operation
instructions, prior to turning on and operating the pump.