Hide thumbs Also See for 3000 MXP:
Table of Contents

Advertisement

D1335704_T3000_MXP_User_Manual
Max input level when
set to minimum input
level
Range, menu
adjustable input gain
Phantom power
voltage
Phantom power
resistor, pin 2
Phantom power
resistor, pin 3
Max phantom power
current pr mic
2 Audio Outputs
1 output (line level) via RCA connector providing audio from far end in addition to dial
tones. This output is used by the monitor. This output also supports S/PDIF.
1 VCR output (line level) via RCA connector providing a mixed signal between audio from
the local side (except from the VCR input) and audio from the far end. This output is
intended for connection to a VCR.
Audio output connector specification:
Connector label
Signal type
Connector (codec)
Output impedance
Max output level when set
to maximum output level
Max output level when set
to minimum output level
Range, menu adjustable
output gain
Volume control attenuation
(audio out 1)
5.1.3

Network

Ethernet:
1 x Ethernet (RJ-45 Jack) LAN interface (10/100 Mb) up to 2 Mbps or 2.3 Mbps depending on the
bandwidth option installed.
To connect the system to a LAN, use the Ethernet cable provided by TANDBERG (or a standard
Ethernet cable).
The cable specification is:
1 ------------ 1
2 ------------ 2
200
6.2 mVpp
22.5 dB (16 steps of
1.5 dB)
24 V +/- 5%
1200 ohms
1200 ohms
12 mA
Audio outputs
Unbalanced
Female RCA/phono, sleeve-ground,
centre-signal
680 ohms
15.3 Vpp
1.15 Vpp
22.5 dB (16 steps of 1.5 dB)
0 to 21 dB + mute (steps of 1.5 dB)
1.17 Vpp
22.5 dB (16 steps of
1.5 dB)
-
-
-
-