Audio board view
1. R102/R202
Here are free slots for custom loads. To activate these loads switches nr. 3 (accessible from
the bottom outside) have to be put into the „on" position. Capacitive or resistive load placed
here will be connected in parallel to all other activated loads at least parallel to the default
load 47k / 100pF.
2. Gain_L/Gain_R
These jumpers change gain by +10dB. The jumpers are activated by default. Using DIP-
switches Nr. 1 the gain is 30dB (off) and 50dB (on) respectively. If the selected gain is too
high the jumpers can be put off.
3. Bass_L/Bass_R
These jumpers activate the Soft Bass Rolloff Filter to avoid high energy low frequency trans-
mission that can damage loudspeaker chassis. Corner frequency of this filter is app. 60 Hz,
attenuation is 6dB/Oct. The jumpers are not activated as default.
4. DC_L/DC_R
By actiation of these jumpers the output capacitors are bridged. The DC jumpers are not
activated as default.
WARNING: When the output capacitors are bridged there can be DC offset voltage pre-
sent at the Black Cube Statement's output connectors. Please make sure that the following
input stage is AC-coupled before activating the DC jumpers. If you do not know the coupling
status of the next following input stage have your setup checked by a dealer or avoid to use
this jumper. DC at the output stage of a power amplifier can destroy loudspeaker chassis!
4
2
3
1