BEARINGS
Model 4200 has ball bearing construction.
Under normal use no additional lubrication is
required.
Cleaning
To avoid accidents always
WARNING
disconnect the tool from
the power supply before cleaning or
performing any maintenance. The tool may
be cleaned most effectively with compressed
dry air. Always wear safety goggles when
cleaning tools with compressed air.
If an extension cord is
WARNING
necessary, a cord with
adequate size conductors that is capable of
carrying the current necessary for your tool
must be used. This will prevent excessive
voltage drop, loss of power or overheating.
Grounded tools must use 3-wire extension
cords that have 3-prong plugs and receptacles.
NOTE: The smaller the gauge number, the
heavier the cord.
Ventilation openings and switch levers must be
kept clean and free of foreign matter. Do not
attempt to clean by inserting pointed objects
through openings.
CAUTION
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated cleaning
solvents, ammonia and household detergents
that contain ammonia.

Extension Cords

RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Tool's
Ampere
Rating
3-6
6-8
8-10
10-12
12-16
14
Certain cleaning agents
and
solvents
Wire Sizes in mm 2
Cord Size in A.W.G.
Cord Length in Feet
Cord Length in Meters
25
50
100 150
15
18
16
16
14
0.75 0.75 1.5
18
16
14
12
0.75 1.0 2.5
18
16
14
12
0.75 1.0 2.5
16
16
14
12
1.0 2.5 4.0
14
12
damage
30
60
120
2.5
4.0
4.0