FURNACE SPECIFICATIONS
B tu h In p u t (U S ) H ig h F ire
O u tp u t (U S ) H igh F ire
B tu h In p u t (U S ) L o w F ire
O u t p u t (U S ) L o w F ire
A . F .U .E .
R a t e d E x te rn al S ta tic (" w .c .)
Te m p e ra tu re R is e (°F )
H ig h S ta g e P re s s u re S w it c h Trip P o in t (" w .c . )
L o w S ta g e P re s s u re S w itc h Trip P o in t (" w . c .)
F ro n t C o ve r P re s s u re S w itc h Trip P o in t (" w .c )
B lo w e r W h e e l (D " x W " )
B lo w e r H o rs e p o w e r
B lo w e r S p e e d s
M a x C F M @ 0 .5 E .S .P .
P o w e r S u p p ly
M in im u m C irc u it A m pa c ity (M C A )
M a x im u m O ve rc u rre n t D e vic e
Tra n s fo rm e r (V A )
H e a t A n t ic ip a t o r (A m p s )
P rim a ry L im it S e t t in g (°F )
A u x ilia ry L im it S e t tin g (°F )
R o llo u t L im it S e t t in g (°F )
F a n D e la y O n H e a tin g
O ff H e at in g *
F a n D e la y O n C o o lin g
O ff C o olin g
F a n D e la y O n - F a n O n ly
G a s S u p p ly P re s s u re (N a tu ra l/ P ro p a n e ) (" w .c .)
M a n ifo ld P re s s u re (N a tu ra l/P ro p a n e ) H ig h S ta g e (" w . c . )
M a n ifo ld P re s s u re (N a t u ra l/ P ro p a n e ) L o w S ta g e (" w .c .)
O rific e S iz e (N a tu ra l/ P ro p a n e )
N u m b e r o f B u rn e rs
V e n t C o n n e c t o r D ia m e te r (in c h e s )
C o m b u s t io n A ir C o n n e c t o r D ia m e te r (in c h e s )
S h ip p in g W e ig h t (lb s . )
* O ff H e a tin g - T h is fa n d e la y tim i n g is a d ju s ta b le (9 0 , 1 2 0 , 1 5 0 o r 1 8 0 s e c o n d s ), 1 5 0 s e c o n d s a s s h ip p e d .
1.
These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.
2.
For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice
changes should only be made if necessary for altitude.
3.
The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the
"A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total
heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times
output.
4.
Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.
M O D E L
A C V C 9 0 7 0 4 C X *
A C V C 9 0 9 0 5 D X *
6 9 ,0 0 0
6 5 ,3 00
4 8 ,0 0 0
4 5 , 0 0 0
9 3 . 3 %
.1 0 - .5 0
3 0 - 6 0
-0 . 5 5
-0 . 2 0
-0 . 3 7
1 0 x 1 0
3 /4
R e fe r to airflo w c h a rts in th is m a n u a l.
1 1 5 -6 0 -1
1 4 .1
1 5
4 0
0 . 7
1 6 0
2 2 0
2 2 0
3 0 s e c s .
1 5 0 s e c s .
5 s e c s .
45 s e c s .
5 s e c s .
7 / 1 1
3 .5 / 1 0
1 . 9 / 6 .0
# 4 3 / # 5 5
3
2
2
1 5 7
ACVC9
9 2 , 0 0 0
8 6 , 5 0 0
6 4 , 0 0 0
6 0 , 1 0 0
9 2 . 7 %
.1 0 - .5 0
3 0 - 6 0
-0 . 5 5
-0 . 2 0
-0 .37
1 1 x 1 0
1
1 1 5 -6 0 -1
1 7 .9
2 0
4 0
0 . 7
1 7 0
1 8 0
2 1 0
3 0 s e c s .
1 5 0 s e c s .
5 s e c s .
4 5 s e c s .
5 s e c s .
7 / 1 1
3 .5 /1 0
1 . 9 / 6 .0
# 4 3 / # 5 5
4
2
2
1 7 2
17