FURNACE SPECIFICATIONS
MOD E L
B tuh Input (US) High Fire
Output (US) High Fire
B tuh Input (US) Low Fire
Output (US) Low Fire
A .F.U.E .
Rated E xternal S tatic (" w.c.)
Temperature Rise (°F)
High Stage P ressure S witch Trip Point (" w.c.)
Low S tage P ressure S witch Trip P oint (" w.c.)
Front Cover P ressure S witch Trip P oint (" w.c)
B lower W heel (D" x W ")
B lower Horsepower
B lower S peeds
M ax CFM @ 0.5 E.S .P .
P ower Supply
M inim um Circuit A mpacity (M CA )
M axim um Overcurrent Device
Transform er (VA )
Heat A nticipator (A mps)
P rimary Limit Setting (°F)
A uxiliary Limit Setting (°F)
Rollout Lim it Setting (°F)
Fan Delay On Heating
Off Heating *
Fan Delay On Cooling
Off Cooling
Fan Delay On - Fan Only
Gas Supply P ressure (Natural/P ropane) (" w.c.)
M anifold Pressure (Natural/P ropane) High Stage (" w.c.)
M anifold Pressure (Natural/P ropane) Low S tage ("w.c.)
Orifice S ize (Natural/P ropane)
Number of B urners
V ent Connector Diameter (inches)
Combustion A ir Connector Diameter (inches)
S hipping W eight (lbs.)
* Off H eating - This fan delay tim ing is adjus table (90, 120, 150 or 180 s econds ), 150 s econds as s hipped.
1.
These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.
2.
For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice
changes should only be made if necessary for altitude.
3.
The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the
"A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total
heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times
output.
4.
Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.
AM VC950453BX * AMV C950704CX* AM VC950905DX * AMV C951155DX*
46,000
69,000
44,300
66,900
32,000
48,000
30,800
46,400
96%
95.5%
.10 - .50
.10 - .50
30 - 60
30 - 60
-0.75
-0.75
-0.30
-0.30
-0.10
-0.10
10 x 8
10 x 10
1/2
3/4
Refer to airflow charts in this m anual.
115-60-1
115-60-1
11.3
14.1
15
15
40
40
0.7
0.7
145
155
150
190
170
200
30 secs.
30 secs.
150 secs.
150 secs.
5 secs.
5 secs.
45 secs.
45 secs.
5 secs.
5 secs.
7 / 11
7 / 11
3.5 / 10
3.5 / 10
1.9 / 6.0
1.9 / 6.0
#43 / #55
#43 / #55
2
3
2
2
2
2
133
157
AMVC95
92,000
115,000
88,800
111,100
64,000
80,000
61,700
77,400
95.7%
95.8%
.10 - .50
.10 - .50
30 - 60
35 - 65
-1.10
-1.10
-0.50
-0.50
-0.10
-0.10
11 x 10
11 x 10
1
1
115-60-1
115-60-1
17.9
17.9
20
20
40
40
0.7
0.7
145
150
180
200
190
200
30 secs.
30 secs.
150 secs.
150 secs.
5 secs.
5 secs.
45 secs.
45 secs.
5 secs.
5 secs.
7 / 11
7 / 11
3.5 /10
3.5 /10
1.9 / 6.0
1.9 / 6.0
#43 / #55
#43 / #55
4
5
3
3
3
3
172
184
15