40" 95% gas furnace units

Advertisement

TECHNICAL INFORMATION MANUAL
GMV95
40" 95% Gas Furnace Units
Refer to Service Manual RS6610004* for installation,
operation, and troubleshooting information.
All safety information must be followed as provided in
the Service Manual.
Refer to the appropriate Parts Catalog for part number
information.
This manual is to be used by qualified, professionally trained HVAC
®
technicians only. Goodman does not assume any responsibility for property
damage or personal injury due to improper service procedures performed by
an unqualified person.
Copyright © 2005
- 2007
Goodman Manufacturing Company, L.P.
Models listed
on page 2.
RT6612012 Rev. 1
June 2007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GMV95 and is the answer not in the manual?

Questions and answers

maintenance dave
February 12, 2025

gmv951155dxbc, #27 the variable speed circ blower motor what is the part number of that part

Subscribe to Our Youtube Channel

Summary of Contents for Goodman GMV95

  • Page 1 Refer to the appropriate Parts Catalog for part number information. This manual is to be used by qualified, professionally trained HVAC ® technicians only. Goodman does not assume any responsibility for property RT6612012 Rev. 1 damage or personal injury due to improper service procedures performed by June 2007 an unqualified person.
  • Page 2: Product Identification

    Goodman will not be responsibile for any injury or property damage arising from improper service or service procedures. If you install or perform...
  • Page 3 Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced...
  • Page 4: Product Design

    4. Installer must supply the following gas line fittings, de- pending on which entrance is used: The GMV95 furnaces are equipped with an electronic ignition Left -- Two 90° Elbows, one close nipple, straight pipe device to light the burners and an induced draft blower to Right -- Straight pipe to reach gas valve.
  • Page 5: Component Identification

    COMPONENT IDENTIFICATION Intell-Ignition Upflow/Horizontal Two-Stage Gas Valve Coil Front Cover Pressure Tap Gas Line Entrance (Alternate) Coil Front Cover Drain Port Pressure Switch(es) Drain Line Penetrations Gas Manifold Drain Trap Combustion Air Intake Connection Blower Door Interlock Switch Hot Surface Igniter Inductor (Not All Models) Rollout Limit Two-Stage Integrated Control Module...
  • Page 6 PRODUCT DIMENSIONS GMV95___XA DISCHARGE DISCHARGE INTAKE PIPE 2" PVC RIGHT SIDE 1 1/2 DRAIN LINE HOLES 1 5/8 UNFOLDED FLANGES UNFOLDED FLANGES FOLDED FLANGES FOLDED FLANGES RIGHT SIDE VIEW Cabinet Size GMV950453BX* 17-1/2 12-15/16 12-1/8 13-5/8 GMV950904CX* 19-1/2 15-15/16 17-1/2 GMV950905DX* 24-1/2 20-7/16...
  • Page 7 11177116 GMV951155DX* Note: All installations above 7,000 ft. require a pressure switch change. For installations in Canada the GMV95 furnaces are certified only to 4500 ft. Note: Replacement pressure switch number is listed below high altitude kit number. Note: All negative pressure readings are in inches of water column (" w.c.).
  • Page 8 PRODUCT DESIGN T.O.D. PRIMARY LIMIT Part Number 20162904 20162905 20162907 Open Setting (°F) GMV950453BX* GMV950704CX* GMV950905DX* GMV951155DX* ROLLOUT LIMIT SWITCHES Part Number 10123517 10123518 10123533 10123537 Open Setting (°F) GMV950453BX* GMV950704CX* GMV950905DX* GMV951155DX* AUXILIARY LIMIT SWITCHES Part Number 10123535 10123537 10123536 10123533 Open Setting (°F)
  • Page 9 Coil Matches: A large array of Amana ® brand coils are available for use with the GMV95 furnaces, in either upflow or horizontal applications. These coils are available in both cased and uncased models, with or without a TXV expansion ®...
  • Page 10 PRODUCT DESIGN Thermostats: The following Amana ® brand thermostats are suggested for use with GMV95 Furnace Models: THERMOSTATS Thermostat Man/Auto Program mable Cool Heat Batt. Pow ered Batt. Bkup 1213406* Man. Or Auto Man. Changeover 1213407 Man. Changeover 1213411 *1213406 is the recommended model f or the GMV 95 f urnaces w hen used w ith a heat pump in a f ossil f uel application.
  • Page 11: Furnace Specifications

    FURNACE SPECIFICATIONS MODEL GMV950453BX* GMV950704CX* GMV950905DX* GMV951155DX* Btuh Input (US) High Fire 46,000 69,000 92,000 115,000 Output (US) High Fire 44,300 66,900 88,800 111,100 Btuh Input (US) Low Fire 32,000 48,000 64,000 80,000 Output (US) Low Fire 30,800 46,400 61,700 77,400 A.F.U.E.
  • Page 12: Blower Performance Specifications

    BLOWER PERFORMANCE SPECIFICATIONS GMV95 Heating Speed Charts GMV950453BX* (Rise Range: 30 - 60°F) GMV950704CX* (Rise Range: 30 - 60°F) Low Stage High Stage Low Stage High Stage Heating Heating Adjust Rise Adjust Rise Speed Speed at .1" - .5" w.c.
  • Page 13 BLOWER PERFORMANCE SPECIFICATIONS GMV95 High (Single) Stage Cooling Speed Charts GMV950453BX* GMV950704CX* GMV950905DX* GMV951155DX* Cooling CFM at Cooling CFM at Cooling CFM at Cooling CFM at Adjust Adjust Adjust Adjust Speed .1" - .8" Speed .1" - .8" Speed .1" - .8"...
  • Page 14 BLOWER PERFORMANCE SPECIFICATIONS GMV95 Continuous Fan Speed Chart GMV950704CX* GMV950453BX* Cooling CFM at Cooling CFM at Adjust Adjust Speed .1" - .8" Speed .1" - .8" w.c. ESP w.c. ESP Minus(-) 380* Minus(-) 380* Normal 380* Normal 380* Plus (+)
  • Page 15 BLOWER PERFORMANCE SPECIFICATIONS GMV95 Circulator Blower Speed Adjustment Switches 4 3 2 1 Note: There is a green LED adjacent to the 4 3 2 1 4 3 2 1 Cooling Heating Normal integrated control module fuse which is Speed...
  • Page 16 PERFORMANCE...
  • Page 17: Wiring Diagrams

    WIRING DIAGRAMS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. 40 V A T R A N S - F O R M E R...
  • Page 18 SCHEMATICS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. LINE XFMR CIRC XFMR LINE PARK COOL HEAT SINGLE HEAT BLOWER ASSEMBLY SCHEMATIC GMV95_____X* MODEL FURNACES This schematic is for reference only.
  • Page 19 SCHEMATICS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.