Choose the Fan Setting (Auto or On or Prog)
Fan Auto is the most commonly selected setting and runs the
fan only when the heating or cooling system is on.
Fan On selection runs the fan continuously for increased air
circulation or to allow additional air cleaning.
Fan Prog will run the fan when the heating or cooling system
is on. In addition, when the thermostat has not called for heat
or cool for more than 60 minutes, it will begin to cycle the fan
for 10 minutes on and 20 minutes off to improve indoor air
quality. This is the Comfort Circulating Fan Feature.
Choose the System Setting
(Cool, Off, Heat, Emer, Auto)
Press the SYSTEM button to select:
Heat: Thermostat controls only the heating system.
Off: Heating and Cooling systems are off.
Cool: Thermostat controls only the cooling system.
Auto: Auto Changeover is used in areas where both heating
and cooling may be required on the same day. AUTO allows
the thermostat to automatically select heating or cooling
depending on the indoor temperature and the selected heat
and cool temperatures. When using AUTO, be sure to set the
Cooling temperatures more than 1° Fahrenheit higher than
the heating temperature.
Emer: Setting is available only when the thermostat is confi g-
ured in HP1 or HP2 mode.
Manual Operation for
Non-Programmable Mode
Press the SYSTEM button to select Heat or Cool and use
the buttons to adjust the temperature to your desired setting.
After selecting your desired settings you can also press the
SYSTEM button to select AUTO to allow the thermostat to
automatically change between Heat and Cool.

PROGRAMMING

Set Current Time and Day
1) Press Menu key to enter installer menu. Then press
Set Time once to indicate hour & AM or PM designation
in clock display.
2) Press and hold either the
reach the correct hour and AM or PM designation.
3) Press Set Time again to display minutes only in clock
display.
4) Press and hold either the
reach the correct minutes.
5) Press Set Time once again to display year.
6) Press and hold either the
reach the correct year.
7) Press Set Time once again to display month.
8) Press and hold either the
reach the correct month.
9) Press Set Time once again to display date of the month
along with day of the week at top row (which is auto-
matic).
10) Press and hold either the
reach the correct day of the month and day of the week
is automatically calculated and displayed at the top row.
11) Press Run Schedule once; now the display will show the
correct time and room temperature.
10
or
touch key until you
or
touch keys until you
or
touch key until you
or
touch key until you
or
touch key until you
Manual Operation (Bypassing the Program)
Programmable Mode
Press the HOLD button and adjust the temperature wherever
you like. This will override the program. The HOLD feature by-
passes the program and allows you to adjust the temperature
manually, as needed. Whatever temperature you set in HOLD
will be maintained 24 hours a day, until you manually change
the temperature or press Run Schedule to cancel HOLD and
resume the programmed schedule.
Program Override (Temporary Override)
Press buttons to adjust the temperature. This will override
the temperature setting for a (default) four hour override
period. The override period can be shortened by pressing
or lengthened by pressing
range from 15 minutes to 7 days.
Example: If you turn up the heat during the morning program,
it will be automatically lowered later, when the temporary hold
period ends. To cancel the temporary setting at any time and
return to the program, press Run Schedule.
If the SYSTEM button is pressed to select AUTO the
thermostat will change to Heat or Cool, whichever ran last. If
it switches to heat, but you want cool, or it changes to cool,
but you want heat, press both buttons simultaneously to
change to the other mode.
Automatic Daylight Saving Calculation
The Real Time Clock will adjust automatically for daylight sav-
ings time, in the following manner:
Increment one hour at 2 AM on the second Sunday of March
and decrement one hour at 2 AM on the fi rst Sunday of No-
vember. (New DST effective 2007).
The daylight saving feature can be enabled or disabled in
installer confi guration menu. Default is DS ON (enabled).
After entering installer confi guration mode, momentarily
press touch key until the display indicates dS (in actual tem-
perature digits) and on (default – in clock digits).
keys will toggle display and operation from on to OFF.
Programming Tip: Copy Program
When programming your thermostat, you may copy the pro-
gram from one day to another day or group of days using the
Copy key. In 7 day programming mode, a day can be copied
to another day or all six other days. In 5/1/1 day programming
mode the weekday (Mon – Fri) program can be copied into
Sat and Sun or either Sat or Sun.
To copy a program from one day to another:
1) In Set Schedule mode, enter the program for the day or
select the day you wish to copy by pressing Advance Day.
2) Press Copy. The display will show "Copy" next to the
SYSTEM key and the day of the week that will be copied.
3) Press Advance Day. The day being copied will be indi-
cated and the other days will be fl ashing.
. Program Override period can
and

Hide quick links: