Table of Contents Introduction ....................Safety Information ................. General Information ................Getting to know your nLite HydroPower System ....System Overview ................New Machine Setup ................Start Up ..................... System Maintenance – Change Resin .......... Operation ....................System Specifications ................. Spare Parts .....................
• Performing unauthorized modification to unit. • Insufficient maintenance. Use only original spare parts by Unger (according to spare parts list, pg. 13). For all inquiries and spare parts orders, it is important to provide detailed information located on the device.
Safety Information General: Please observe applicable rules and regulations, including all accident prevention procedures. Unger is not liable for damage to application areas, plumbing system components nor persons. Ensure application area has sufficient water drainage. If unit will be idle for a prolonged period of time, ensure feed water supply is shut-off.
Installation & Operating Instructions Purified water is delivered to the waterfed wash pole by flexible hose from the nLite HydroPower system. This introduces a risk of tripping by both worker and general public. Identify work area with appropriate signage. Any surface that becomes wet must be identified with appropriate signage to direct pedestrians and workers away from work area.
Page 6
Installation & Operating Instructions Getting to Know Your nLite HydroPower System TDS Meter FastLock Lever Output Valve Quick Connect Adapter Housing with Rugged Outside Appearance QuickChange FloWater Resin Bag Distribution Filter (Packed inside unit) System Inlet Connection for On/Off Valve...
Operating Instructions System Overview • Unger nLite HydroPower systems contain mixed bed ion exchange resin to “filter” impurities out of ordinary drinking water, converting it into a powerful cleaning agent commonly referred to as PureWater. Such impurities are referred to as total dissolved solids (TDS) and are measured in parts per million (ppm).
Standard HydroPower DI Filter Filter System 30% MORe PURe WATeR FloWater Technology The revolutionary Unger FloWater Technology distributes the water FloWater Technology uniformly through the filter system so disburses that the resin is most effectively used. water through resin Tap water goes in 2.
Installation & Operating Instructions New Machine Set-Up 1. Unpack Unit: Inspect the nLite HydroPower system and all components. Read warnings and operating manual. 2. Inspection & Scope of Delivery: Refer to above illustration; perform visual inspection and take inventory of the following items that should be shipped with the system, then test system for functionality: a.
If well water system is the source, it is recommended that a water quality analysis be performed prior to application. 3. Unger recommends testing the water supply for TDS (total dissolved solids) prior to working. Higher TDS levels reduce the DI system‘s capacity. Conversely, lower TDS levels will increase the amount of water the system is able to produce.
Operating Instructions System Maintenance - Change Resin NOTE: Unger does not recommend the use of bulk resin with nLite HydroPower systems. The use of bulk resin, with its widely varying properties, may cause damage to the system due to excessive expansion when water is introduced.
Installation & Operating Instructions Operation 1. Periodically inspect the HydroPower system during use. Ensure hoses are properly attached. Inspect system for leaks and proper fit of top cap assembly. 2. Take care when working to ensure there is enough slack in waterfed wash pole tubing.
Spare Parts NOTe: Due to safety reasons, unauthorized modifications are not allowed. Original parts and accessories are specifically designed for this device. Any liability by the manufacturer for damages resulting from modifications to the device or from using parts other than original parts is excluded. PRODUCT INFO PART #...
Need help?
Do you have a question about the nLite Hydro Power HP06T and is the answer not in the manual?
Questions and answers