York AFFINITY BHZ Technical Manual page 64

2 - 5 ton 60 hertz affinity series
Hide thumbs Also See for AFFINITY BHZ:
Table of Contents

Advertisement

718419-YTG-D-0613
BHX 024 - 060 Heat Pump With/Without Electric Heat
Compressors
Models
Volt
(Tons)
RLA LRA
BHX024
208/230-1-60 10.2
52
(2.0)
208/230-1-60 16.6
82
BHX036
(3.0)
208/230-3-60 11.1
58
460-3-60
4.5
29
208/230-1-60 21.1
96
BHX048
(4.0)
208/230-3-60 13.4
88
460-3-60
6.4
41
208/230-1-60 25.6
118
BHX060
(5.0)
208/230-3-60 17.6
135
460-3-60
9.0
62
1. Minimum Circuit Ampacity.
2. Maximum Over Current Protection per standard UL 1995.
3. Fuse or HACR circuit breaker size installed at factory or field installed.
64
Supply
OD Fan
Blower
Motors
Motor
MCC
FLA
FLA
Model
None
2NH04500506
2NH04500706 5.6/7.5
16
0.9
4.3
2NH04501006
2NE04500706 5.6 / 7.5
2NE04501006 7.5 / 10
None
2NH04500506
2NH04500706 5.6/7.5
2NH04501006
26
1.1
6.8
2NH04501506 11.3/15
2NE04500706 5.6 / 7.5
2NE04501006 7.5 / 10
2NE04501506 11.3 / 15
None
17
1.1
6.8
2NH04501025
2NH04501525 11.3/15
None
7
0.6
3.4
2NH04501046
2NH04501546
None
2NP04501006
2NP04501506 11.3/15
2NP04502006
33
2.6
6.8
2NP04502506 18.8/25
2NE04501006 7.5 / 10
2NE04501506 11.3 / 15
2NE04502006 15 / 20
2NE04502506 18.8 / 25
None
2NP04501025
21
2.6
6.8
2NP04501525 11.3/15
2NP04502025
2NP04502525 18.8/25
None
2NP04501046
10
1.3
3.4
2NP04501546
2NP04502046
2NP04502546
None
2NP04501006
2NP04501506 11.3/15
2NH04502006
40
2.5
9.1
2NP04502506 18.8/25
2NE04501006 7.5 / 10
2NE04501506 11.3 / 15
2NE04502006 15 / 20
2NE04502506 18.8 / 25
None
2NH04501025
28
2.5
9.1
2NH04501525 11.3/15
2NH04502025
2NH04502525 18.8/25
None
2NP04501046
14
1.3
4.6
2NH04501546
2NH04502046
2NP04502546
Electric Heat Option
kW
Stages
Amps
-
-
-
3.8/5
1
18.1/20.8
2
27.1/31.3
7.5/10
2
36.1/41.7
2
27.1 / 31.3
2
36.1 / 41.7
-
-
-
3.8/5
1
18.1/20.8
2
27.1/31.3
7.5/10
2
36.1/41.7
2
54.2/62.5
2
27.1 / 31.3
2
36.1 / 41.7
2
54.2 / 62.5
-
-
-
7.5/10
1
20.8/24.1
1
31.3/36.1
-
-
-
10
1
12
15
1
18
-
-
-
7.5/10
2
36.1/41.7
2
54.2/62.5
15/20
2
72.2/83.3
2
90.3/104.2
2
36.1 / 41.7
2
54.2 / 62.5
2
72.2 / 83.3 90.3 / 104.2
2
90.3 / 104.2 112.8 / 130.2
-
-
-
7.5/10
1
20.8/24.1
1
31.3/36.1
15/20
2
41.7/48.1
2
52.1/60.1
-
-
-
10
1
12
15
1
18
20
2
24.1
25
2
30.1
-
-
-
7.5/10
2
36.1/41.7
2
54.2/62.5
15/20
2
72.2/83.3
2
90.3/104.2 156.4/173.8
2
36.1 / 41.7
2
54.2 / 62.5
2
72.2 / 83.3 90.3 / 104.2
2
90.3 / 104.2 112.8 / 130.2
-
-
-
7.5/10
1
20.8/24.1
1
31.3/36.1
15/20
2
41.7/48.1
2
52.1/60.1
-
-
-
10
1
12
15
1
18
20
2
24.1
25
2
30.1
2
Max Fuse
/
1
3
MCA
Breaker
(Amps)
Size
(Amps)
18
25
40.5/44
45/45
51.8/57
60/60
63.1/70
70/80
33.9 / 39.1
35 / 40
45.1 / 52.1
50 / 60
28.7
35
51.2/54.7
60/60
62.5/67.7
70/70
73.8/80.7
80/90
96.4/106.8
100/110
33.9 / 39.1
35 / 40
45.1 / 52.1
50 / 60
67.7 / 78.1
70 / 80
21.8
30
47.8/51.8
50/60
60.9/66.9
70/70
9.6
15
24.7
25
32.2
35
35.8
45
80.9/87.9
90/90
103.5/113.9
110/125
126.1/139.9
150/150
148.6/166
150/175
45.1 / 52.1
50 / 60
67.7 / 78.1
70 / 80
100 / 110
125 / 150
26.2
35
52.2/56.2
60/60
65.2/71.3
70/80
78.3/86.3
80/90
91.3/101.3
100/110
12.7
15
27.7
30
35.3
40
42.8
45
50.3
60
43.6
60
88.7/95.7
100/110
111.3/121.7
125/125
133.9/147.8
150/150
175/175
45.1 / 52.1
50 / 60
67.7 / 78.1
70 / 80
100 / 110
125 / 150
33.6
45
59.7/63.7
70/70
72.7/78.7
80/80
85.7/93.7
90/100
98.8/108.8
100/110
17.2
25
32.2
35
39.7
40
47.2
50
54.7
60
Johnson Controls Unitary Products

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Affinity bhqAffinity bhxAffinity bhq series

Table of Contents