York AHV18B Technical Manual
York AHV18B Technical Manual

York AHV18B Technical Manual

Single piece ecm air handlers for use with split-system air conditioners & heat pumps

Advertisement

TECHNICAL GUIDE
SINGLE PIECE ECM
AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
AIR CONDITIONERS & HEAT PUMPS
MODELS: AHV18 THRU 60
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at:
www.york.com
Additional rating information can be found at:
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replace-
ment or closing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The AHV Air Handler line offers the ultimate in comfort, sound
and application flexibility. The air handler is shipped ready to be
installed in upflow, horizontal left or right position, with minor
adjustments. No special kits are required to install this deluxe
product.
Air handlers are shipped with "Flex-coils" without a factory
installed metering device. Flex coil models allow these coils to
be used with R-22 or R-410A for added flexibility to meet refrig-
erant choices. An orifice metering device or a R-410A TXV
should be installed in the field to meet your system require-
ments.
FEATURES
Thermostatic Expansion Valve - Provides the ultimate refrig-
erant control required for today's high efficient product. The
UPG bolt-on TXV provides easy installation to convert the air
handler to the required refrigerant, which is a true bolt-on
design that does not require brazing to replace or install.
Rust-proof Plastic Drain Pans - The vertical and horizontal
drain pans in these units are made of a fiberglass reinforced
thermoset polymer that will not rust or compromise stability at
high temperatures.
Insulated Cabinet - All air handler cabinets are thermally insu-
lated with 3/4" foil faced insulation to prevent sweating.
Factory Sealed - Achieves 2% or less total airflow leakage rate
at duct leakage test conditions for system airflow verification.
Durable Finish Inside and Out - Air handler casings are made
of pre-painted galvanized steel which provides a better paint to
steel bond that resists corrosion and rust creep. All internal coil
sheet metal parts are made of G60 galvanized or prepainted
G30 galvanized steel.
Filters - All models have internal filter racks provided for use
with 1" thick standard size filters.
Electric Heat Kits - The 6HK series of field installed electric
heat kits are available for installation friendly and easy service
applications. These 6HK kits have heat capacities from 2 kW to
25 kW to meet the application requirements.
ECM Variable Speed Motor - Designed for efficient, quiet oper-
ation with added indoor comfort control. With the use of a
humidistat, the system will monitor the humidity in the home
ISO 9001
Certified Quality
and automatically keep the desired humidity level in both winter
Management System
and summer seasons. The ECM motor utilizes only 24% of the
energy used by standard blower motors to reduce your overall
heating and cooling costs.
The climate comfort system allows dealer to customize comfort
settings based on regional location.
Communications - These models may be connected as part of
a communications system using a 4-wire connection bus.
824755-YTG-C-0912

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AHV18B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for York AHV18B

  • Page 1 The climate comfort system allows dealer to customize comfort settings based on regional location. Visit us on the web at: Communications - These models may be connected as part of www.york.com a communications system using a 4-wire connection bus. Additional rating information can be found at: www.ahridirectory.org WARRANTY Standard 5-year limited parts warranty.
  • Page 2: Dimensions & Duct Connection Dimensions

    Dimensions Refrigerant Dimensions Wiring Knockouts Connections Models Line Size Height Width Depth Power Control Liquid Vapor AHV18B/AHV24B/AHV30B 17 1/2 16 1/2 13-29/32 16 1/2 7/8 (1/2) AHV36C 21 1/2 21 1/2 17-13/32 1-3/8(1) 7/8 (1/2) 1-23/32 (1-1/4) AHV42D/AHV48D/AHV60D 24 1/2...
  • Page 3: Cooling Capacity

    50/143.3 85/72 37.9 33.7 28.3 23.3 80/67 31.8 22.5 17.6 75/62 26.4 21.5 16.7 11.6 70/57 20.7 18.4 15.8 13.5 AHV18B 85/72 49.7 43.2 36.9 28.4 80/67 42.1 35.1 28.8 22.5 75/62 33.7 21.4 14.7 70/57 26.5 23.8 20.3 16.9 85/72 38.7...
  • Page 4: Application Factors - Rated Cfm Vs. Actual Cfm

    824755-YTG-C-0912 COOLING CAPACITY (Continued) MBH@ Evap. Temp. and Corresponding R-410A Pressure (°F/PSIG) Entering Air Models Rated CFM Dry/Wet Bulb (°F) 35/107.9 40/118.9 45/130.7 50/143.3 85/72 56.6 51.1 42.8 35.6 80/67 48.6 41.1 34.8 27.6 75/62 39.4 18.3 70/57 30.5 26.6 23.1 19.6 85/72...
  • Page 5: Physical & Electrical Data - Cooling Only

    3. 75C, copper wire only. If wire other than non-plated, 75C ambient, copper wire is used, consult applicable tables of the NEC and local codes.. ELECTRICAL HEAT: MINIMUM FAN SPEED Air Handler Models Nom. kW Heater Kit Models @240V AHV18B AHV24B AHV30B AHV36C AHV42D AHV48D...
  • Page 6 824755-YTG-C-0912 ELECTRIC HEAT PERFORMANCE DATA: 208/230-1-60 & 208/230-3-60 kW Staging Total Heat Heater Nominal kW W1 Only W1 + W2 @240V Models 208V 230V 208V 230V 208V 230V 208V 230V 6HK(0,1)6500206 6HK(0,1)6500506 12.3 15.0 6HK(0,1)6500806 19.7 24.1 6HK(0,1)6501006 24.6 30.1 6HK(1,2)6501306 12.5 11.5...
  • Page 7 MOP. Min Wire Size (AWG) Models @240V 208V 230V 208V 230V 208V 230V 6HK(0,1)6500206 10.0 14.2 15.4 6HK(0,1)6500506 20.0 25.0 27.9 AHV18B 6HK(0,1)6500806 32.0 38.0 42.9 6HK(0,1)6501006 40.0 46.7 52.9 6HK(0,1)6500206 10.0 14.2 15.4 6HK(0,1)6500506 20.0 25.0 27.9 6HK(0,1)6500806 32.0 38.0...
  • Page 8 824755-YTG-C-0912 ELECTRICAL DATA FOR MULTI-SOURCE POWER SUPPLY: 208/230-1-60 Min. Circuit Ampacity Min. Wire Size (AWG) Total Heater 208V 230V 208V 230V 208V 230V Heater Handlers Amps Models Circuit Circuit Circuit Models @240 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd...
  • Page 9: Typical Applications

    824755-YTG-C-0912 ELECTRICAL DATA FOR MULTI-SOURCE POWER SUPPLY: 208/230-3-60 Min. Circuit Ampacity Min. Wire Size (AWG) Total Heater 208V 230V 208V 230V 208V 230V Heater Air Handler Models Amps Models Circuit Circuit Circuit @ 240V AHV36C 6HK16502025 46.2 29.5 25.0 32.9 28.9 AHV42D AHV48D...
  • Page 10: Typical Thermostat Connection

    AC OR HP CONTROL WIRING - Air Handler & UPG HP Systems Two Stage Touch Screen Air Handler Air Conditioner/Heat Pump H/P with York Guard VI Board & Copeland “Ultra Tech” Communicating Communicating Communicating Control Conventional Application - Not Hot Heat Pump...
  • Page 11 824755-YTG-C-0912 AIR FLOW DATA (CFM) High/Low Speed Cooling and Heat Pump CFM AHV18 AHV24 AHV30 AHV36 Cool Tap ADJ Tap High High High High 1035 1150 1380 1035 1208 1000 1200 1050 1080 1035 AHV42 AHV48 AHV60 Cool Tap ADJ Tap High High High...
  • Page 12: Wiring Diagrams

    824755-YTG-C-0912 WIRING DIAGRAMS SEE INSTALLATION INSTRUCTIONS FOR PROPER WHEN INSTALLING HEATER KIT, BE SURE THE BLOWER SPEED IS SET TO THE SPEED SPECIFIED FOR THE AIR HANDLER/HEATER KIT LOW VOLTAGE FIELD WIRING CONNECTIONS. COMBINATION ON THIS UNIT'S INSTALLATION INSTRUCTIONS. HEATER KITS: 6HK*6500206 6HK*6500506 CONTROL...
  • Page 13 824755-YTG-C-0912 HEATER KITS: HEATER KITS: 6HK06501825 6HK06501025 6HK06501525 REL3 REL3 REL6 REL2 REL5 REL2 REL1 REL4 REL1 HEATER KITS: 6HK16502025 6HK16502525 COMPONENT CODES GND – EQUIPMENT GROUND REL3 REL6 FL – FUSIBLE LINK REL2 REL5 HE – HEATING ELEMENT LS – LIMIT SWITCH REL –...
  • Page 14 NOTES Subject to change without notice. Published in U.S.A. 824755-YTG-C-0912 Copyright © 2012 by Johnson Controls, Inc. All rights reserved. Supersedes: 824755-YTG-B-0612 York International Corp. 5005 York Drive Norman, OK 73069...

This manual is also suitable for:

Ahv24bAhv30bAhv36cAhv42dAhv48dAhv60d