Connection Examples - ABB Knox Original Instructions Manual

Safety and process lock
Table of Contents

Advertisement

Connection examples

Connection example – Knox 2A with signal for unlocking from other safety system
Knox 2A
EDEN
ADAM
2
1
7
6
2
1
7
B1
T1
B2
R1
ABB JOKAB SAFETY
JOKAB SAFETY
Type: Vital 1
Type: Vital 1
NB: The info reset signal is HIGH when the outer handle on Knox is set in its upward position.
NB: The system will lock Knox if there is no signal for unlocking.
NB: Vital 1 is used to monitor the locking
Warning! The system must be connected using a fuse of max 6A.
Warning! Signal for unlocking must be a safe signal from system in the same enclosure.
2TLC172250M0201, rev. D
2013-08-12
+24 V
Reset
Sensor
Motor
5
3
4
8
6
5
3
4
8
A1
A1
A2
A2
9
Info reset
Info locked
Signal for unlocking
Safe signal
www.abb.com/jokabsafety