Technical Data - ABB Knox Original Instructions Manual

Safety and process lock
Table of Contents

Advertisement

7

Technical data

Manufacturer
Address
Power supply
Operating voltage
Power consumption
Time delay t (in/out Eden)
General
Protection class
Ambient temperature
Size
Holding force
(in opening direction)
Lock function
Weight
Material
Colour
Connector
Mechanical life
EMC
Vibration resistance in 3 directions
(according to IEC 60068-2-6)
Shock resistance in 3 directions
(according to IEC 60068-2-27)
Warning! Knox locks mechanically. Forcing the lock may damage Knox permanently.
2TLC172250M0201, rev. D
2013-08-12
ABB JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
24 VDC ± 10 %
Knox 2A
Electronics: 70 mA (in locked position)
Lock/lock inverse: 135 mA (when
locking/unlocking)
Information output: Max 10 mA
Total max: 160 mA
t <60 µs
IP65
+5...+55°C
See drawing
Unlocked: 5,000 N (10,000 N ultimate breaking strength)
Locked: 5,000 N (10,000 N ultimate breaking strength)
Knox 2A: S/M – bistable, unlocked and locked with voltage
Knox 2X: M – internal locking electronics; locked when signal is applied, unlocked otherwise
(bistable at power failure)
Door part:: ~ 3.14 kg
Frame part: ~ 0.79 kg
Stainless steel
Silver
Knox 2A: M12 8-pole male
Knox 2X: M12 5-pole male
105 cycles
EN 62061:2005, Annex E
10-59 Hz, 0.7 mm P-P
59-500 Hz, 5 g
10 sweep cycles, 1 oct/min
15 g, 11 ms half sine
± 3 shocks
23
Knox 2X
Electronics: 150 mA
Lock: 5 mA (when locking/locked)
Information output: Max 10 mA
Total max: 165 mA
www.abb.com/jokabsafety

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents