SOFTWARE OPERATION INSTRUCTIONS
5.2.4> Dynamic range control
Press DRC button(or COMPRESSSION/LIMIT), the interface is as following:This compression just check the
HF signal, once the signal reach the limit, it will compress the HF and LF synchronously(synchronous action
is for the balance of HF and LF)
Five parameters in the dynamic range table is adjustable(the inner parameter is no name,
not adjustable)
Threshold:
Ratio:
RMS Estimator Time: The checking time of limit value of compression
Release time:
Attack time:
5.2.5> The delay setting of output channel
Mainly adjust the distance of sound center to make sure the sound center is same. Press DELAY with mouse,
the 5.2.4 interface will be showed, the right side is the delay adjust range from 0.0208ms to 21.2292ms.
Is the limit value of compression, adjustable from 0dB to -49.5dB
Compression ratio,adjustable from 1:1 to & :1
Release compression time after the checking that the signal level is
under the limit
Start up time after checking that the signal level is above the limit.