  • Page 3: Product Features

    S1200Na PRODUCT FEATURES Two transducers 2.1 way full range plastic speaker, coaxial components, computer simulation design. Compact, high sensitivity, big power active full range plastic speaker. All transducers with horn loading. Built in DSP amplifier, all parameters of speaker can be precisely adjusted according to user's own style through RS-232,RS-485,USB connector with computer.
  • Page 4 S1200Na FREQUENCY RESPONSE 1 3 0 3 6 0.0 C LIO d B S D eg 1 2 0 2 5 2.0 1 1 0 1 4 4.0 1 0 0 3 6.0 - 7 2.0 - 1 8.0 1 00...
  • Page 5 S1200Na WATERFALL 0 .0 - 10 1 .3 - 20 - 30 2 .7 - 40 - 50 4 . 0 ms 1 50 2 00 5 00 1 0k 2 0k C LIO 1 20 1 8 0.0 C LIO...
  • Page 6 S1200Na HORIZONTAL DIRECTIVITY The data of S1200Na horizontal directivity were collected by testing the speaker system in a big anechoic chamber. 100Hz 160Hz 200Hz 400Hz 630Hz 1.0kHz 1.6kHz 2.5kHz 3.15kHz 6.3kHz 10kHz 16kHz The scale is stepped by 6dB increment.
  • Page 7 S1200Na VERTICAL DIRECTIVITY The data of S1200Na vertical directivity were collected by testing the speaker system in a big anechoic chamber. 100Hz 160Hz 200Hz 400Hz 630Hz 1.0kHz 1.6kHz 2.5kHz 3.15kHz 6.3kHz 10kHz 16kHz The scale is stepped by 6dB increment.
  • Page 8: Amplification Module

    S1200Na AMPLIFICATION MODULE S 1200Na POWER:300W+300W ACTIVE 3 WAY FULL RANGE ELECTRONIC COMPENSATION SPEAKER LINE INPUT LINE OUTPUT PEAK VOLUME RS-485 INPUT RS-485 OUTPUT RS-232 Beta Three This series of products are authorized to be produced by Elder Audio Manufactory with Germany computer aided design software and testing system according to IEC standard.
  • Page 9: Control Software

    S1200Na SOFTWARE APPLICATION GUIDE How to get the software The software is stored in the CD with equipment packaging. The latest version also may be downloaded from the company website. Software installation System requirement: Microsoft Windows 98/XP or above version. Display resolution should be 1024*768 or above.
  • Page 10 S1200Na SOFTWARE APPLICATION GUIDE 1.3> Program: Obtain the information of currently used configuration file (Disconnection status),or the information of current program in the equipment(Connection status). On disconnection status, only Display Current Program No " " " , Display Current Program Name , "...
  • Page 11 S1200Na SOFTWARE APPLICATION GUIDE Picture 3 If found device, shown as Figure 4: Picture 4 Devices online are listed at left, the right part shows the information of the device chosen by user. If user want to use the config file that opens from computer, "...
  • Page 12 S1200Na SOFTWARE APPLICATION GUIDE After connecting successfully, the software will update the display automatically, and show the information of currently connected device, and current program used by device, see Figure 5: Picture 5 On above interface, click corresponding function button, and executing those operation that you want.
  • Page 13 S1200Na SOFTWARE APPLICATION GUIDE 3.2>User also may save the parameters in the device, total max six programs may be saved through " Save as current program in device " under program menu. See Figure 7: " " Picture 7 According to the different file source, the two ways are available for recall the existing configuration file.
  • Page 14 S1200Na SOFTWARE APPLICATION GUIDE 4. Change the information of the device that is online. Device information means the identifier of device, such as the description of device position etc, Include ID and device name. After connecting, it may be changed through clicking "...
  • Page 15: Application Examples

    S1200Na SOFTWARE APPLICATION GUIDE 6. Disconnection. After finishing the adjustment of parameters, the current parameters may be saved into the device for the next power on operation. If user does not save the program into device, all the changes based on previous parameters will not be saved.
  • Page 16 S1200Na APPLICATION EXAMPLES 2) Then select the Program Number that will be saved into device: Then click "OK" button, the Program No.1 has been saved as Program No.2,and the current program auto changed to No.2(and the Program No.1 just be uploaded to PC has not been changed) 3) Then select "Edit Current Program Name"...
  • Page 17 S1200Na APPLICATION EXAMPLES Changed to " my concert hall " as the bellow figure 5) Click "OK" button, thus the "Current Program Name:" on the main interface has been changed to "my concert hall". 6) Select " List Program & Recall" command in "Program" menu, the result in the program list of the...
  • Page 18 S1200Na APPLICATION EXAMPLES 2.Save the program which is uploading from device as a file in computer. Operation for file is only effected on disconnection status. If on connection status, " Edit current program name is immeditaly valid(auto save into the device). If want to use the config file for later use with another "...
  • Page 19 S1200Na APPLICATION EXAMPLES Edit Program Name to "my modified program 3", then click "OK" button. 3) Then select "Save As" command in "File" menu. 4) In the " File Name(N) " frame, input " next hall.asc " ,then click "...
  • Page 20 S1200Na APPLICATION EXAMPLES 3.Downloading a file into device, and save as program in device. 1) After downloading the config file into DEVICE(only to RAM, before select " Save As Current Program In Device command, the parameters have not saved into FLASH ROM!) "...
  • Page 21 S1200Na APPLICATION EXAMPLES Click OK button ,then the parameters of config file(next_hall.asc) have been saved as program No.4 in " " device. The "Current Program No" and the "Current Program Name" are corresponding to File, as bellow figure: List as below...
  • Page 22: Installation

    S1200Na INSTALLATION DIMENSIONS 416mm 280mm Top view Front view 423mm Side view Back view...
  • Page 23: Warranty

    S1200Na Speakers are guaranteed against malfunction due to defects in materials or workmanship for a period of three (3) years from the date of original purchase.