Technical Data - Clarke MA50 15B CLARKE380B Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

BRUSH /PAD DRIVER CLEANING
CAUTION !
It is advisable to wear protective gloves when cleaning the brush/pad because there may be sharp debris.
1.
Remove the brush/pad as shown in "Machine Use" section.
2.
Clean and wash the brush/pad with water and detergent.
3.
Check the brush bristles for integrity and wear. If necessary, replace the brush.
4.
Check the pad for wear. If necessary, replace the pad driver.
RECOVERY TANK MAINTENANCE
CAUTION !
It is advisable to wear protective gloves when cleaning the tank and vacuum/suction assembly because there may be sharp debris.
1.
Move the machine to the appointed draining area.
2.
Turn off the main switch.(47)
3.
Remove the recovery tank, (2) clean and rinse both solution/recovery tank, and drain out.
4.
Remove vacuum gasket & fi lter. Clean and re-install.
5.
Check the recovery tank lid gasket and the vacuum rubber connector (18) for wear. Replace if necessary.
NOTE
The gasket ring of recovery tank and the rubber connector between two tanks create vacuum in the tank. If necessary, replace them.

TECHNICAL DATA

MODEL
Machine length / width / height
Solution tank capacity
Recovery tank capacity
Wheel diameter
Brush motor
Vacuum motor
Solenoid valve
Maximum gradient when working
Sound level
Standard Batteries
Batteries size
Power cable length
Cleaning productivity
Squeegee width
Brush diameter
Brush rpm
Charger
Machine net weight
Machine weight(with charger and package)
Carton spec
7/2014
INSTRUCTIONS FOR USE
MA50 15B
770x500x550MM
15L
15L
254MM
24V/250W
24V/250W
24V
2%
70dBA
Dry:(2×12V)24V 33Ah
196 x 130 x 175mm
N / A
750m2/hour
490mm
380mm
150rpm
Input 110-224Vac,50-60HZ;Output 24Vdc,5A
60kg
65kg
780x415x590MM
56091128 - MA50 15B
ENGLISH - A
A - 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents