Squeegee Installation - Clarke MA50 15B CLARKE380B Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

BRUSH/PAD DRIVER INSTALLATION AND DISASSEMBLY
NOTE
Only install manually. If automatically installed, it will wear brush hub.
Make sure that the tanks are empty before removing the brush.
1.
Turn off the machine.
2.
Lay down the machine in the position shown in fi gure 2. Pull up lift lever (26) to raise the squeegee. (33).
3.
Mount the brush or pad driver onto the drive wheel hub and then rotate counterclockwise until it locks, as indicated in fi gure 3.
4.
To remove the brush/pad, rotate the brush/pad clockwise until it is released from drive hub.
WARNING !
Do not turn on the machine in this position as below. In case of brush/pad come out or cause injury.

SQUEEGEE INSTALLATION

1.
Turn off the machine. (47)
2.
Pull down the squeegee lift lever (26) to put down the squeegee in the "working" position.
3.
Lay down the machine in this position as shown in fi gure2.
4.
Loosen the two knobs (55) on the squeegee and slide the squeegee into the slots on the squeegee brackets.
5.
Tighten the knobs securely. (unscrew the knobs, if to remove)
6.
To replace the front/rear squeegee, (56/57) unscrew the thumb knobs (37).
7/2014
INSTRUCTIONS FOR USE
56091128 - MA50 15B
ENGLISH - A
FIGURE 2
FIGURE 3
A - 5