AH 360-720 Preface Safety notes Page 3 1. Important notes Page 4-5 1.1 For your safety Page 4 1.2 Operating for the first time Page 5 1.3 About use Page 5 2. Structure and operating principle Page 6-7 2.1 Structure of the appliance Page 6 2.2 Accessories/special accessories...
Preface With your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: – effective extraction thanks to the so-called “Coanda effect” – low operating noise To ensure that you will be able to use this appliance in all its diversity, read through the operating and assembly instructions conscientiously before operating it for the first time.
Safety notes Read And Save These Instructions. WARNING - TO REDUCE THE RISK OF FIRE, WARNING - TO REDUCE THE RISK OF INJURY ELECTRIC SHOCK, OR INJURY TO PERSONS, TO PERSONS IN THE EVENT OF A RANGE OBSERVE THE FOLLOWING: TOP GREASE FIRE, OBSERVE THE FOLLOWING: a.) Use this unit only in the manner intended by the...
1. Important notes 1.1 For your safety Damaged appliances must not be operated. Isolate the appliance from the mains during every maintenance operation. To do this, remove the Connecting cables must not come into contact with mains plug or actuate the corresponding fuse. hot cooking surfaces.
If the problem has nothing to do with the power supply, please contact your specialist Conscientiously read through the operating and dealer or your local Gaggenau after-sales service. assembly instructions before operating the appliance for the first time.
2.3 Operating principle This extractor hood swiftly and silently extracts all odours produced while cooking. You can set different intensity levels depending on the intensity of odours. The fan in the extractor hood sucks in the kitchen vapours and passes them through the grease filter to outdoors.
3. Operation 3.1 Switching on and off Switching on – Turn the “Ventilation level” control knob to the ventilation level you require (Fig. 6). – The set level is displayed. After a power failure, the extactor will not go on again automatically.
3.2 Special functions Intensive level You should select the intensive level when browning and frying in an open pan. Switching on: (Fig. 9) – Turn the control knob to a ventilation level (1-3). – Press the intensive level key. The intensive level symbol appears on the display.
4. Cleaning and care Caution! Over-greased filters are a fire risk! Pay attention to cleaning the grease filter on a regular basis. Cleaning the grease filters: (Grease filter saturation) symbol flashes on the display after an operating time of 30 hours. Flashing of this symbol signals to you that the grease filters have to be cleaned.
Page 12
Cleaning the glass plates Apply commercially available window cleaning agent with a soft, moist cloth. To facilitate cleaning, you can detach the glass plates as follows: Detach the grease filters. In the extractor hood, you will find two openings on the upper side through which you can lift the glass plates singly with a blunt object (e.g.
If the power supply is functioning correctly, but your appliance still does not work, please contact your Gaggenau dealer who will provide you with the address and telephone number of your nearest manufacturer’s authorized service agent or contact Gaggenau USA on (800) 828-9165.
6. Assembly instructions 6.1 Technical data Weight: 41 kg without ventilation duct Dimensions: 47 ´ ´ x 22 ´ ´ / 1198 x 560 mm Electrical connection Pay attention to the rating plate data. The appliance must only be connected by an authorised specialist.
The applicable regulations of the energy supply 6.2 Installation companies and the regional construction WARNING - TO REDUCE THE RISK OF FIRE, regulations must be observed when installing ELECTRIC SHOCK, OR INJURY TO PERSONS, the hood. OBSERVE THE FOLLOWING: The minimum distance from the worktop to the a.) Installation work and electrical wiring must be bottom edge of the wall hood is for electrical done by qualified person(s) in accordance with...
Page 16
Flexible aluminium pipes, corrosion-protected Depending on the ceiling height, the following duct sheet metal pipes and exhaust air pipes whose units are at your disposal for exhaust air operation: material conforms to fire B1 in accordance with LK 360-010: Ventilation duct for ceiling heights of DIN 4102 can be used.
Page 17
Proceed as follows: 15 ( ") Important: Before marking the securing holes, make sure that no electricity or water lines or other lines are laid at the drilling points in the wall. ") Important: There are two handles on top of the hood.
Page 18
– Secure the hood to the wall using the 4 screws b (Fig. 18). – Establish the pipe connection. – Establish the electrical connection. – Extract the protective file from the chimney paneling. Note: Avoid damaging the sensitive stainless steel surfaces.
Page 19
GAGGENAU HAUSGERÄTE GMBH 5551 McFADDEN AVENUE P.O. BOX 10 02 50 · D - 80076 MÜNCHEN HUNTINGTON BEACH, CA 92649 GERMANY Y (0 89) 45 90-01 Y (800) 828-9165 · FAX (714) 901-0979 FAX (0 89) 45 90-23 47 www.gaggenau.com/us...