Buderus Logano G234X Installation And Maintenance Instructions Manual page 4

Gas-fired boiler
Hide thumbs Also See for Logano G234X:
Table of Contents

Advertisement

1
Explanation of symbols and safety information
Danger from escaping flue gases
B Make sure that the vent pipes and gaskets are not
damaged.
B Use silicone as sealing compound.
B The boiler must not be fitted with a barometric damper
or a thermally controlled flue flap downstream of the
flue socket.
B Connect only one boiler to each venting system or
chimney flue.
B Connection of another boiler may cause serious injury
or death.
B The venting system piping must not feed into another
air extraction duct.
B Do not route the flue system piping through or inside
another air extraction duct, for example where there is
a masonry or prefabricated chimney flue.
Danger of explosion of flammable gases.
B Work on gas components may only be carried out by
qualified and authorized personnel.
B Mounting, gas and flue connection, initial
commissioning, electrical connection and maintenance
activities must only be carried out by a trained service
provider.
Dangers posed by explosive and easily
combustible materials
B Do not use or store easily-combustible materials
(paper, lace curtains, clothing, thinners, paints, etc.)
near the boiler.
B Maintain a clearance of 16.2 inches (415 mm) from the
boiler.
Combustion air
B Keep the combustion air free of corrosive substances
(e. g. halogenated hydrocarbons that contain chlorine
or fluorine compounds). This will help prevent
corrosion.
Danger from electric shock when the boiler is open.
B Before opening the boiler:
Disconnect the heating system from the electrical
power supply by means of the emergency shutoff
switch or the heating system circuit breaker on the
main fuse panel.
B It is not enough to only switch off the control unit.
B Take measures to ensure that the heating system
cannot be switched on again unintentionally.
Danger due to short-circuits
To prevent short circuits, only
B use genuine Buderus wiring.
4
Set-up, installation, commissioning
B Correct and proper installation and adjustment of the
burner and the control panel are the fundamental
requirements for safe and economical operation of the
boiler.
B The boiler may only be installed or converted by an
approved heating contractor.
B Never change any parts in contact with flue gas.
B Only qualified electricians are permitted to carry out
electrical work. Installation regulations must be
complied with.
B The hot water tank may only be used for heating
domestic hot water.
B Never shut off safety valves!
Water may escape from the safety valve for the hot
water system and piping when the water is being
heated.
Inspection/maintenance
B Servicing and repairs may only be carried out by an
approved heating contractor.
B Immediately correct all faults to prevent system
damage.
B The operator is responsible for the general and
environmental safety of the heating system.
B Use only genuine spare parts! Damage caused by the
use of parts not supplied by Buderus is not covered by
the Buderus warranty.
B Recommendation for users: take out a maintenance
and servicing contract with an approved heating
contractor covering annual servicing and condition-
based maintenance.
Instructing the customer
B Explain to the customer how the boiler works and how
to operate it.
B Inform the customer that he/she must not carry out any
alterations or repairs.
Logano G234X - Technical specifications are subject to change without prior notice.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents