Buderus Logano G201 Operating Instructions Manual

Buderus Logano G201 Operating Instructions Manual

Solid fuel boiler
Hide thumbs Also See for Logano G201:

Advertisement

Operating Instructions

Logano G201
Solid fuel boiler
DANGER!
If these instructions are not followed exactly, a fire
or explosion may be caused with serious property
damage or loss of life and serious injury.
– Do not store or use gasoline or any other flam-
mable liquids or vapors in the vicinity of this system
or any other heating system.
– The heating system must only be installed and
serviced by a qualified service company or qualified
service provider.
For the operator
Please read carefully before
use.

Advertisement

Table of Contents
loading

Summary of Contents for Buderus Logano G201

  • Page 1: Operating Instructions

    – The heating system must only be installed and serviced by a qualified service company or qualified service provider. Logano G201 For the operator Please read carefully before use.
  • Page 2 Regardless of whether heat, hot water or ventilation – with a Buderus product you will have highly-efficient heating technology in the proven Buderus quality, which will make you comfortable reliably for a long time. We manufacture using the latest technologies and take care that our products are efficiently attuned to one another.
  • Page 3: Table Of Contents

    5.1.2 Monthly cleaning ......18 Troubleshooting ......20 Logano G201 - Subject to technical modifications.
  • Page 4: Safety Instructions And Symbol Key

    V Always keep system openings (doors, maintenance cover, fill openings) closed during operation. V Only use approved fuels. V Do not cover or reduce the size of ventilation openings in doors, windows and walls. Logano G201 - Subject to technical modifications.
  • Page 5: Information About The Appliance

    V The service technician is obligated to inform the boiler Designated use operator about the operation and the correct, safe The Logano G201 solid fuel boiler is a heating boiler for operation of the boiler. coal and wood firing (split log firing) in single and multi- V In case of danger of explosion, fire, escaping combus- family houses.
  • Page 6: Disposal

    V Packing materials made of wood and paper can be burned in the boiler. V Dispose of packaging in an environmentally responsi- ble manner. V Dispose of old devices in an environmentally responsi- ble manner at an authorized disposal site. Logano G201 - Subject to technical modifications.
  • Page 7: Product Description

    Information about the appliance Product description The Logano G201 is a solid fuel boiler and approved for fueling with coal and wood chunks. The boiler consists of: – Air vent [1] – Ash pan door [2] – Fuel filler door [3] –...
  • Page 8: General Instructions About The Fuels Wood

    V Operate the boiler at the recommended operating tem- peratures. V Only heat the boiler with the recommended fuels Chapter 3.1 and 3.2). V Remove tar accumulations with the cleaning scraper when the boiler is warm. Logano G201 - Subject to technical modifications.
  • Page 9: Storing Fuel

    – Protect storage location against snow and rain. – Do not store any damp coal on dry coal. – Plan the coal delivery when the coal storage is 75 % empty. – If possible, store new and old coal separately. Logano G201 - Subject to technical modifications.
  • Page 10: Start-Up And Operation

    V Later on, check the operating pressure monthly, top- ping up heating water and bleeding the boiler and radi- ators if needed. Logano G201 - Subject to technical modifications.
  • Page 11: Checking The Operating Pressure

    V Bleed the heating system via the purge valves on the boiler piping. V Top up with additional water if the pressure drops as a result of bleeding the system. V Remove the hose from the boiler fill & drain valve. Logano G201 - Subject to technical modifications.
  • Page 12: Setting The Firing Controller

    If the air vent is closed completely, there is no complete combustion. Tar accumulates on the heating surfaces, which requires more cleaning effort. Tab. 4 Settings for the firing controller depending on the outdoor temperature Logano G201 - Subject to technical modifications.
  • Page 13: Heating Up The Boiler

    V Remove the segment plate [1]. Fig. 7 Removing the segment plate Segment plate Bolt V To increase the draft of the boiler, open the exhaust flap. Fig. 8 Open the exhaust flap Logano G201 - Subject to technical modifications.
  • Page 14 Large types of anthracite coal and coke burn longer; with too great a quantity of fuel, the output can be reduced. Check and stoke the fire at short intervals. Fig. 11 Closing the exhaust flap Logano G201 - Subject to technical modifications.
  • Page 15: Energy Absorption

    On each firing, fill the ignition chamber with coal up to the begin- ning of the fuel fill door. V Close the fuel filler door [1] and exhaust flap ( Fig. 13 below). Logano G201 - Subject to technical modifications.
  • Page 16: Constant Heating Mode (Fire Continues Burning Overnight)

    V Open the air flap a crack (0.2 inches). V Extinguish the fire with water. V Close the exhaust flap after successful heating up. Logano G201 - Subject to technical modifications.
  • Page 17: Cleaning And Maintenance

    WARNING: Risk of system damage due to insufficient maintenance and cleaning! Larger quantities of ashes in the fuel space can cause overheating of and damage to the boiler. V Remove the ashes from the boiler regular- Logano G201 - Subject to technical modifications.
  • Page 18: Frequent Cleaning

    V Insert the waste steam plate [1] and close the fuel filler Fig. 15 Heat exchanger heater flue, cleaning door [2]. Waste steam plate V Take the steps described under 5.1.1. Fuel filler door Logano G201 - Subject to technical modifications.
  • Page 19 V Close the inspection aperture with the cleaning cover [1]. Check that the seal is seated correctly. V Screw the cleaning cover [1] back on with two wing nuts. Fig. 16 Cleaning the flue gas header Cleaning cover Flue gas header Logano G201 - Subject to technical modifications.
  • Page 20: Troubleshooting

    Inform heating contractor and check/ increase minimum boiler water tem- perature and ensure a minimum tem- perature of 131 °F for the return due to a suitable setting of the mixing valve Tab. 5 Overview of faults Logano G201 - Subject to technical modifications.
  • Page 21 Notes Logano G201 - Subject to technical modifications.
  • Page 22 Notes Logano G201 - Subject to technical modifications.
  • Page 23 Notes Logano G201 - Subject to technical modifications.