– The heating system must only be installed and serviced by a qualified service company or qualified service provider. Logano G201 For the operator Please read carefully before use.
Page 2
Regardless of whether heat, hot water or ventilation – with a Buderus product you will have highly-efficient heating technology in the proven Buderus quality, which will make you comfortable reliably for a long time. We manufacture using the latest technologies and take care that our products are efficiently attuned to one another.
V Always keep system openings (doors, maintenance cover, fill openings) closed during operation. V Only use approved fuels. V Do not cover or reduce the size of ventilation openings in doors, windows and walls. Logano G201 - Subject to technical modifications.
V The service technician is obligated to inform the boiler Designated use operator about the operation and the correct, safe The Logano G201 solid fuel boiler is a heating boiler for operation of the boiler. coal and wood firing (split log firing) in single and multi- V In case of danger of explosion, fire, escaping combus- family houses.
V Packing materials made of wood and paper can be burned in the boiler. V Dispose of packaging in an environmentally responsi- ble manner. V Dispose of old devices in an environmentally responsi- ble manner at an authorized disposal site. Logano G201 - Subject to technical modifications.
Information about the appliance Product description The Logano G201 is a solid fuel boiler and approved for fueling with coal and wood chunks. The boiler consists of: – Air vent [1] – Ash pan door [2] – Fuel filler door [3] –...
V Operate the boiler at the recommended operating tem- peratures. V Only heat the boiler with the recommended fuels Chapter 3.1 and 3.2). V Remove tar accumulations with the cleaning scraper when the boiler is warm. Logano G201 - Subject to technical modifications.
– Protect storage location against snow and rain. – Do not store any damp coal on dry coal. – Plan the coal delivery when the coal storage is 75 % empty. – If possible, store new and old coal separately. Logano G201 - Subject to technical modifications.
V Later on, check the operating pressure monthly, top- ping up heating water and bleeding the boiler and radi- ators if needed. Logano G201 - Subject to technical modifications.
V Bleed the heating system via the purge valves on the boiler piping. V Top up with additional water if the pressure drops as a result of bleeding the system. V Remove the hose from the boiler fill & drain valve. Logano G201 - Subject to technical modifications.
If the air vent is closed completely, there is no complete combustion. Tar accumulates on the heating surfaces, which requires more cleaning effort. Tab. 4 Settings for the firing controller depending on the outdoor temperature Logano G201 - Subject to technical modifications.
V Remove the segment plate [1]. Fig. 7 Removing the segment plate Segment plate Bolt V To increase the draft of the boiler, open the exhaust flap. Fig. 8 Open the exhaust flap Logano G201 - Subject to technical modifications.
Page 14
Large types of anthracite coal and coke burn longer; with too great a quantity of fuel, the output can be reduced. Check and stoke the fire at short intervals. Fig. 11 Closing the exhaust flap Logano G201 - Subject to technical modifications.
On each firing, fill the ignition chamber with coal up to the begin- ning of the fuel fill door. V Close the fuel filler door [1] and exhaust flap ( Fig. 13 below). Logano G201 - Subject to technical modifications.
V Open the air flap a crack (0.2 inches). V Extinguish the fire with water. V Close the exhaust flap after successful heating up. Logano G201 - Subject to technical modifications.
WARNING: Risk of system damage due to insufficient maintenance and cleaning! Larger quantities of ashes in the fuel space can cause overheating of and damage to the boiler. V Remove the ashes from the boiler regular- Logano G201 - Subject to technical modifications.
V Insert the waste steam plate [1] and close the fuel filler Fig. 15 Heat exchanger heater flue, cleaning door [2]. Waste steam plate V Take the steps described under 5.1.1. Fuel filler door Logano G201 - Subject to technical modifications.
Page 19
V Close the inspection aperture with the cleaning cover [1]. Check that the seal is seated correctly. V Screw the cleaning cover [1] back on with two wing nuts. Fig. 16 Cleaning the flue gas header Cleaning cover Flue gas header Logano G201 - Subject to technical modifications.
Inform heating contractor and check/ increase minimum boiler water tem- perature and ensure a minimum tem- perature of 131 °F for the return due to a suitable setting of the mixing valve Tab. 5 Overview of faults Logano G201 - Subject to technical modifications.