Test Run
Display
Master Outdoor Unit Inverter
1
Compressor High Discharge
Temperature
Slave1 Outdoor Unit Inverter
2
Compressor High Discharge
Temperature
3
2
Slave2 Outdoor Unit Inverter
3
Compressor Discharge High
Temperature
Slave3 Outdoor Unit Inverter
4
Compressor High Discharge
Temperature
Master Outdoor Unit Constant
1
Speed Compressor High
Discharge Temperature
Slave1 Outdoor Unit Constant
2
Speed Compressor High
Discharge Temperature
3
3
Slave2 Outdoor Unit Constant
3
Speed Compressor High
Discharge Temperature
Slave3 Outdoor Unit Constant
4
Speed Compressor High
Discharge Temperature
High Pressure of Master Outdoor
1
Unit
High Pressure of Slave1 Outdoor
2
Unit
3
4
High Pressure of Slave2 Outdoor
3
Unit
High Pressure of Slave3 Outdoor
4
Unit
Low Pressure of Master Outdoor
1
Unit
Low Pressure of Slave1 Outdoor
2
Unit
3
5
Low Pressure of Slave2 Outdoor
3
Unit
Low Pressure of Slave3 Outdoor
4
Unit
84
84
Outdoor Unit
Outdoor Unit
Title
System is turned off by Master Outdoor Unit Inverter
Compressor High Discharge Temperature
System is turned off by Slave1 Outdoor Unit Inverter
Compressor High Discharge Temperature
System is turned off by Slave2 Outdoor Unit Inverter
Compressor High Discharge Temperature
System is turned off by Slave3 Outdoor Unit Inverter
Compressor High Discharge Temperature
System is turned off by Master Outdoor Uunit Constant
Speed High Discharge Temperature
System is turned off by Slave1 Outdoor Unit Constant
Speed High Discharge Temperature
System is turned off by Slave2 Outdoor Unit Constant
Speed High Discharge Temperature
System is turned off by Slave3 Outdoor Unit Constant
Speed High Discharge Temperature
System is turned off by excessive increase of high
pressure of Master Outdoor Unit
System is turned off by excessive increase of high
pressure of Slave1 Outdoor Unit
System is turned off by excessive increase of high
pressure of Slave2 Outdoor Unit
System is turned off by excessive increase of high
pressure of Slave3 Outdoor Unit
System is turned off by excessive decrease of low
pressure of Master Outdoor Unit
System is turned off by excessive decrease of low
pressure of Slave1 Outdoor Unit
System is turned off by excessive decrease of low
pressure of Slave2 Outdoor Unit
System is turned off by excessive decrease of low
pressure of Slave3 Outdoor Unit
Cause of Error