Disassembly Procedures
!

Control Panel Removal

1. Disconnect power to vent hood.
2. Remove screws securing top retractable cover.
3. Slide cover down to gain access to the support rods.
NOTE: Insert a prop rod under the vent hood before
performing step 4. Once the support rod screws
are removed, the vent hood will lower.
4. Remove screws securing cover to support rods.
5. As the vent hood lowers, label and disconnect
electrical connections and the ducting.
6. Remove grease filters and covers, see "Grease Filter/
Grease Filter Cover Removal" procedure.
7. Remove screws securing all vent hood covers.
8. Remove screws securing control panel assembly.
NOTE: A small, square-type wrench is necessary to
remove screws.
9. Remove screws securing vent hood canopy to base.
10.Remove screws securing control panel to base.
11. Label and disconnect control panel connections.
12.Rotate and remove control panel from base.
13.Reverse procedure to reinstall control panel.
Control Panel

Blower Motor Removal

1. Disconnect power to vent hood.
2. Remove screws securing top retractable cover.
3. Slide cover down to gain access to the support rods.
NOTE: Insert a prop rod under the vent hood before
performing step 4. Once the support rod screws
are removed, the vent hood will lower.
4. Remove screws securing cover to support rods.
5. As the vent hood lowers, label and disconnect
electrical connections and ducting.
6. Remove grease filters and covers, see "Grease Filter/
Grease Filter Cover Removal" procedure.
7. Remove screws securing all vent hood covers.
8. Remove control panel, see "Control Panel Removal"
procedure.
9. Disengage supports from side of motor.
©2004 Maytag Services
WARNING
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
10. Label and disconnect blower electrical connections
and remove blower motor.
11. Reverse procedure to reinstall blower motor.
NOTE: When reinstalling motor, ensure washers
removed in Step 9 are installed over edge of
blower housing.

Capacitor Removal

1. Disconnect power to vent hood.
2. Remove grease filters and covers, see "Grease Filter/
Grease Filter Cover Removal" procedure.
3. Remove screws securing capacitor cover.
4. Discharge capacitor by connecting a one end of a
jumper wire to the capacitor terminal with the diode
connection and the other end to a well insulated
screwdriver. Touch the screwdriver to a chassis
ground. Remove jumper wire.
5. Remove screws securing capacitor cover.
6. Label and disconnect capacitor electrical connections
and remove capacitor.
7. Reverse procedure to reinstall capacitor.

Filter Spring Clip Removal

1. Disconnect power to vent hood.
2. Remove grease filters and covers, see "Grease Filter/
Grease Filter Cover Removal" procedure.
3. Locate and remove clip assemblies installed in vent
housing by gently pulling clip toward the front and up.
4. Reverse procedure to reinstall the filter spring clip.