Specifications & Performance Claims
These models are efficiency rated. The efficiency rating is valid only at the minimum salt dose. These softeners have
a demand initiated regeneration (D.I.R) feature that complies with specific performance specifications intended to
minimize the amount of regenerant brine and water used in their operation.
These softeners have a rated softener efficiency of not less than 3,350 grains of total hardness exchange per pound of
salt (based on sodium chloride) and shall not deliver more salt than their listed rating or be operated at a sustained
maximum service flow rate greater than their listed rating. These softeners have been proven to deliver soft water for
at least ten continuous minutes at the rated service flow rate. The rated salt efficiency is measured by laboratory tests
described in NSF/ANSI Standard 44. These tests represent the maximum possible efficiency that the system can
achieve. Operational efficiency is the actual efficiency after the system has been installed. It is typically less than the
rated efficiency, due to individual application factors including water hardness, water usage, and other contaminants
that reduce a softener's capacity.
Model Code
Rated Softening Capacity (Grains @ Salt Dose)
Rated Efficiency (Grains/Pound of Salt @ Minimum Salt Dose)
Water Used During Regeneration @ Minimum Salt Dose
Total Water Used Per Regeneration @ Maximum Salt Dose
Rated Service Flow Rate
Amount of High Capacity Ion Exchange Resin
Pressure Drop at Rated Service Flow
Water Supply Max. Hardness
Water Supply Max. Clear Water Iron
Water Pressure Limits (minimum / maximum)
Water Temperature Limits (minimum / maximum)
Minimum Water Supply Flow Rate
Intermittent Flow @ 15 psi
Maximum Drain Flow Rate
* Intermittent flow rate does not represent the maximum service flow rate used for deter-
mining the softener's rated capacity and efficiency. Continuous operation at flow rates
greater than the service flow rate may affect capacity and efficiency performance.
These systems conform to NSF/ANSI Standard 44 for the specific performance claims as
verified and substantiated by test data.
Variable Salt Dose: The salt dose is selected by the electronic controls at regeneration
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
4
Model Nos. 625.75130 & 625.75230
time based on the amount needed.
PERFORMANCE CLAIMS
Contaminant
Influent Challenge Level
Barium
Radium 226/228
SPECIFICATIONS
Maximum Allowable
10 ±10% mg/L
25 pCi/L
hF32
10,500 @ 2.3 lbs.
27,600 @ 8.5 lbs.
35,000 @ 14.7 lbs.
4,565 @ 2.3 lbs.
3.6 gallons / 1,000 grains
38.1 gallons
10.0 gpm
1.08 cu. ft.
11 psig
95 gpg
8 ppm
20 - 100 psi
5 - 49 °C
3 gpm
10.0 gpm*
2.0 gpm
Product Water Level
2.0 mg/L
5 pCi/L