USING THE HOB - INDUCTION
Cook Zone
LHF
LHR
RHF
RHR
Note The Power Boost function will only
operate for a limited time and is also
under thermal control. This means the
power boost will deactivate automati-
cally if the product is hot, to protect the
internal electronic components of the
hob and to prevent the cookware from
overheating.
Minute Minder
The minute minder buzzes when the time
set has expired. Does not switch off any
zone. To operate
•
Turn on the hob, using the on/off key.
•
Select the timer "CL" (do not activate
any cook zone).
•
Set the right hand digit up to 9 min-
utes (Single Minutes Units) and wait
a couple of seconds.
•
The display will now indicate for you
to set the left hand digit, up to 90
minutes (10 Minute Units).
•
The timer is now set and begins
counting down. (No zone indicator
light should be set).
•
You can now use the hob as normal.
Normal Max
Power (9) kW
1.4
1.4
1.9
1.4
Boosted Power
kW
-
2.00
2.3
-
When the time is up.
•
The corresponding indicator in the
timer display will flash, the timer will
beep.
•
Touch any control to stop the beep-
ing.
Timer auto switch off
The timer can be set to automatically turn
off a cooking zone.
All four cook zones can be simultaneously
timed to turn off automatically.
Cook zones can be set for a maximum
time of 99 minutes.
Maximum
Permissible
Setting on
Paired Zone
9 (LHR)
8 (LHR)
8 (RHR)
6 (RHF)