WARNING!
C

5 Commissioning the device

Risk of injury due to hot air and inert gases.
Use caution when operating the hot air tool, because hot air can
cause burns. Caution: use of inert gases in an enclosed area can
cause asphyxiation.
Please read carefully the safety instructions in the attached
booklet, the safety guidelines given in these operating
instructions and the operating instructions of your control unit
before putting the WXHAP 200 into operation. Also observe
the safety precautions described herein.
1. Carefully unpack hot air tool WXHAP 200.
2. Make sure that the control unit is OFF.
3. Place the WXHAP 200 hot air tool into the stand (4).
4. Insert the electrical plug (1) of the WXHAP 200 into the
socket on the control unit and lock the plug into place by turning it
slightly to the right.
5. Push the air hose of the WXHAP 200 (2) onto the air nipple on
the control unit.
6. Turn on the control unit at the power switch and set the
temperature and air flow. Also read and observe the operating
instructions of your control unit.
5.1
Operating guidelines
Excessively long nozzle threads can damage the
!
AUTION
heater core of your tool.
The max. thread depth for hot air nozzles is 5 mm (0.2 "). Use of
longer threads will cause irreparable damage to the heater core.
Use of Non-Weller nozzles may result in damage to the hot air
tool and void the warranty.
Pay attention to the correct thread depth of the screw-in
nozzles!
Always use Weller original hot air nozzles!
The WXHAP 200 is supplied with an 8 mm socket wrench. Use this
to replace the nozzles. Tighten the nuts on the heater core using the
supplied open-end wrench.
Note
To use the nozzles, screw the supplied nozzle adaptor (5)
(T005 87 617 28) into the WXHAP 200 using the 8 AF socket
wrench. You can use the same nozzles as those for the
WXHAP 200.
Replacement hot air tools are supplied preset and can be connected
and used without any need for readjustment.
To check the hot air temperature, it is recommended that you use a
special test nozzle (T005 87 278 08) which mates with a sheathed
thermocouple (Ø 0.5 mm).