EcoSmart GWL10US Service Supplement Manual page 29

Electronic washing machine
Table of Contents

Advertisement

Primary Source - Mechanical.
Action
1) Check that the rotating basket assembly is not jammed to the agitator with any foreign object
that may be caught under the agitator skirt.
2) Check that the clutch teeth are not locked together with dirt, lint, etc.
3) Make sure the basket is not overloaded with too many clothes.
4) If none of the above appear to be at fault, then check the air bell at the bottom of the inner
basket for leaks.
Secondary Source - Motor Controller Module.
Action
If the machine is empty of water at fault it is possible that the pump circuit is faulty and has caused
a pump out during wash. This would cause the basket to re-engage during agitate and the Motor
Controller Module to display this fault. Replace Motor Controller Module.
161.
(10100001) Hardware / EEPROM Supply Mismatch
The Motor Controller Module checks the hardware configuration (i.e. 110v or 230v) against its
EEPROM table on power up. The Hot Valve feedback circuit divider voltage determines the
hardware supply selection. Should there be a mismatch, this error is flagged.
Primary Source - Motor Controller Module.
Action - Replace Motor Controller Module.
162.
(10100010) Brake Deceleration Time-out Fault
During the brake mode the Motor Controller Module has detected that the basket has not come to a
stop in the permitted time once dropping below 100rpm. This fault has been installed for software
testing only.
163.
(10100011) Valve Reset Pin Connect Fault
The Motor Controller Module has sensed the PCB connection is open circuit. The cold valve
cannot operate with this condition.
Primary Source - Motor Controller Module.
Action - Replace Motor Controller Module.
164.
(10100100) Brake Function Time-out Fault
This fault indicates that the Motor Controller Module has been attempting to brake for 20 seconds.
As all spin loads should come to rest within 10 seconds something has gone wrong during the brake
to prevent the basket stopping in time.
Primary Source - Wiring.
Action
Measure/check the motor harness connectors and motor for discontinuity. This can be done by
taking a resistance measurement between phases of the motor harness at the Motor Controller
Module end Nominal resistance should be around 12.5 ohms.
Secondary Source - Motor Controller Module
Action - Replace Motor Controller Module.
192.
(11000000) Motor PMW Reset Pin Connect Fault

Hide quick links: