Download Print this page

Spares; User Information; Water And Electrical Connections; Final Assembly And Testing - Heatrae Sadia Streamline Installation Manual

Over/undersink single point-of-use open outlet electrical water heater

Advertisement

6

WATER AND ELECTRICAL CONNECTIONS

Earth Post at
1.
12 o'clock
YOUR HEATRAE SADIA TAP PACK INCLUDES A SPLASH SHIELD ASSEMBLY
position
WHICH MUST BE FITTED.
Outlet bosses.
Connections from the heater to the tap set must be via the compression
nuts on the Splash Shield Assembly. Refer to the Tap Pack instructions
for details. If necessary use only PTFE tape,
2.
up the outer clamp nut.
FIG 14
3.
blue to N; green/yellow to E.

FINAL ASSEMBLY AND TESTING

WARNING: BEFORE SWITCHING ON, ENSURE HEATER IS FULL OF WATER.
1.
2.
3.
TOUCH ELEMENT TERMINALS.
4.
5.
opened by removing the adhesive tape covering it. The slot in the centre of
the backplate top edge must be closed by affixing the adhesive tape provided
over the slot. See FIGs 2 and 6 for location of drainage slots.
6.
hot tap fully open, adjust the flow restrictor as specified on page 2. Turn off
the flow.
7.
shield assembly is correctly located.
8.
will expand during heating causing the tap to drip.
MADE AWARE OF THIS

FAULT FINDING

SYMPTOM
POSSIBLE CAUSE
No hot water
No water in heater
Blown cut-out or open
circuit element
Faulty thermostat
Heater installed incorrectly
No water when valve turned on Blockage in valve or vented tap Dismantle and clean as necessary
Insufficient mains pressure
Excessive expansion of tank Too much back pressure
Water too hot
Faulty thermostat
Element fitted incorrectly
Any problems which cannot be solved using the above chart should be directed to the Service Department at
Heatrae Sadia.
Remove the red caps from the Inlet and Outlet plus white grommets.
Connect the white plastic nuts to the Inlet and
DO NOT OVERTIGHTEN.
NEVER USE PLUMBER'S PASTE.
If using the cable grip, remove the red plug, insert the cable and nip
Make connections to the terminal block: red or brown to L; black or
CHECK EARTH POST ON ELEMENT PLATE IS IN 12 O'CLOCK POSITION.
CHECK WATER INLET IS ON RIGHT HAND SIDE.
CHECK THERMOSTAT CAPILLARY IS HELD IN POSITION AND DOES NOT
Please leave warning label attached for future reference.
The drainage slot in the centre of the backplate lower edge must be
Turn on the water and fill until water flows freely from the Outlet. With the
Check for leaks and refit covers and securing screws ensuring splash
Set the thermostat in mid position, switch on the power. Water in the container
THE OWNER SHOULD BE
to avoid erroneous complaints about leaky taps.
REMEDY
Fill as detailed on page 5 or 6
Replace cut-out or element and check water
heater is filled with water before switching on
Replace thermostat
Check fitting instruction followed fully
Check for minimum water pressure (See page 3 )
Fit flow reducing valve and adjust flow rate as
detailed on page 2
Replace thermostat
Check element is in correct position for the
particular mounting mode. Earth post must
always be in 12 o'clock position

SPARES

CODE
DESCRIPTION
95604200
Spout 12'' Chrome plus Gaiter
95604656
Telescopic Spout
95604659
12'' Light Grey Spout (Domestic)
95605445
Thermostat Knob
95605446
On/Off Knob
95606758
EPA 1kW
95606759
EPA 3kW
95607852
Foam Insulation 7lt
95607853
Foam Insulation 10lt

USER INFORMATION

IT IS NORMAL FOR THE TAP OR SPOUT TO DRIP DURING HEATING AS
STREAMLINE IS AN OPEN OUTLET HEATER.
CONTROLS
When used Oversink, the heater has 2 controls: flow and temperature
setting (see page 3 for temperature options available).
TEMPERATURE CONTROL
Temperature at minimum setting ideal
for freezing protection. Move control
anticlockwise for maximum setting.
DESCALING
In hard water areas, minerals build up
on the element and in the bottom of the container, around the outlet. When this
happens, there will be gradual fall off in flow. To descale, proceed as follows:
FIG 16
Isolate electricity supply and turn off water. Remove both covers. Drain the heatre
through the appropriate boss.
OVERSINK MODE
Remove blank plug at the top left of heater. The outlet standpipe is now visible. Clean out the cross hole using a pipe
cleaner or similar device. Check sealing washer in blank plug and re-seal. If in any doubt over the seal, replace with a
new one. Remove element plate and inspect element. If scaled, clean carefully by hand.
Do not use de-scaling fluids.
UNDERSINK MODE
Remove oulet pipe from water heater. The outlet fitting will then be visible. Proceed as for Oversink.
GUARANTEE
Goods are guaranteed and sold subject to our standard conditions of sale. A copy of these conditions will be
supplied on application. In the event of the unit being returned under the terms of guarantee, it should be
despatched direct to your supplier and not to Heatrae Sadia Heating.
This guarantee does not affect the statutory rights of the consumer.
WARNING: THIS HEATER IS NOT GUARANTEED AGAINST DAMAGE BY FROST.
CODE
DESCRIPTION
95608784
Inner Container 7lt
95608785
Inner Container 10lt
95608786
Outercase 7lt
95608789
Bottom Moulding - white
95611711
EP Gasket (Pk 10)
95612512
Thermostat
95612514
Printed Circuit Board
95612515
Thermostat Locking Pin
95612516
Wiring Set
Fig 15 - Oversink model as normally supplied
DO NOT USE POINTED INSTRUMENT.
7

Advertisement

loading