Horizontal Termination - Empire Comfort Systems DVP42DP31N-2 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

NOTICE: Termination cap should pass through the wall firestop
from the exterior of the building. Adjust the termination
cap to its final exterior position on the building.
WARNING
Termination cap must be positioned so that arrow is pointing
up.
Attach the termination cap with the four wood screws provided.
Before attachment of the termination, run a bead of silicone sealant
rated above 250°F on its outside edge too, so as to make a seal
to the exterior wall.
NOTICE: Wood screws can and should be replaced with appropriate
fasteners for use on stucco, brick, concrete or other types
of siding.
CAUTION
If exterior walls are finished with vinyl siding, (or materials that
could become discolored or warp) it is necessary to install a
vinyl siding standoff.
31457-1-0513

HORIZONTAL TERMINATION

The vinyl siding standoff will be installed between the vent termination
and the exterior wall. See Figure 47. This horizontal vent termination
bolts onto the flat portion of the vinyl siding standoff, so an air space
will exist between the wall and the termination cap.
Figure 47
Page 29

Advertisement

Table of Contents
loading

Table of Contents