KitchenAid KHTU160 Series Installation Instructions And Use And Care Manual page 4

30" (76.2 cm) and 36" (91.4 cm) traditional series vented and non-vented range hoods
Table of Contents

Advertisement

Available languages

Available languages

Now start...
1.
Put a thick protective
covering over cooktop, set-in
range or countertop to protect
from damage or dirt.
If installing over a freestanding
range, disconnect and move the
range to provide easier access to
the upper cabinet and rear wall.
Slide range onto cardboard or
hardboard before moving to
prevent damaging floor covering.
2.
Place hood on a protective
cover with filters facing down.
3.
Determine which venting
method (roof, wall or non-vented)
will be used.
• The hood is factory-set for roof
venting.
• For non-vented installations, go
to Step 4.
seal plate
If venting through the wall,
remove seal plate from back of
hood and vent connector from top
of hood. Reinstall vent connector
onback of hood and seal plate on
top of hood.
top
knockout
back knockout
4.
Remove knockout from the
wiring opening (top or back) to be
used.
4
5.
Mark centerlines on rear wall
and upper cabinet bottom.
For non-vented installations:
Extend centerline up onto soffit
above hood.
6.
Align centerlines of template
with centerlines marked on rear
wall and upper cabinet bottom.
Tape template in place. Mark
location of the four holes used to
secure hood to upper cabinet.
7.
Depending on your
installation, mark location of the
wiring hole or vent cutout in
upper cabinet or back wall needed
as shown on template.
8.
vent
Remove template.
connection
9.
Drill four 3/16" (5.0 mm)
diameter holes through upper
cabinet for the hood mounting
screws.
10.
wiring hole.
11.
Make the vent cutout for
3-1/4" x 10" (8.3 x 25.4 cm)
rectangular vent system. Note: It
is recommended that vent system
be installed before installing
hood.
12.
do not use
these
filters face up.
knockouts
centerlines
template
Drill the 1-1/2" (4.0 cm)
Turn the hood over so
13.
Rotate deflector away
from filters. Pull grease filter
handles toward back of hood to
release locking tabs. Lift filters up,
remove from hood and set aside.
screw locations
14.
Remove 2 screws from
light panel tabs. On light panel
surface directly behind tabs, push
toward back of the hood to move
tabs out through the slots.
Remove panel and set aside with
screws.
remove
screws
wiring
box cover
15.
Remove 2 screws from
wiring box cover located in the
right hand rear corner and remove
cover. Attach the U.L.- or CSA-
listed strain relief to the hood
wiring hole being used.
16.
Turn hood over so filters
face down.
screw

Advertisement

Table of Contents
loading

This manual is also suitable for:

Khtu100 series

Table of Contents