Battery Installation or Replacement

A single 9V battery (NEDA 1604, 6F22, or 006P) supplies
power to operate the Fluke 27. Referring to Figure 1, use
the following procedure to replace the Fluke 27 battery:
1.
Turn the rotary switch to OFF, and remove the test
leads.
2.
Lift the instrument stand on the back of the Fluke 27,
then remove the four black, #6 X 32, Pozi-drive®
screws from the battery cover.
3.
Pull the battery cover straight out from the back of
the meter. (A coin-slot in the side of the battery cover
facilitates removal.)
16
4.
Remove and disconnect the battery.
5.
Snap the battery connector to the terminals on the
new battery, then slide the battery into the battery
compartment.
6.
Insert the battery spacer/cover into the Fluke 27,
then start the four screws removed in step 2. Press
firmly on the battery cover while tightening the
screws in a diagonal pattern.