KitchenAid KHTU100 Series Installation Instructions And Use And Care Manual page 5

30" (76.2 cm) and 36" (91.4 cm) traditional series vented and non-vented range hoods
Table of Contents

Advertisement

Available languages

Available languages

17.
Attach hood damper into
vent connector. Make sure that
damper swings freely. If wall or
roof vent system cap has a
damper, DO NOT attach damper
that came with hood.
Non-vented (recirculating)
installations only: Assemble the
vent system you will use over the
roof vent opening but do not
attach the vent system yet.
A
Measure distance A and transfer it
to the centerline on the soffit.
Mark and cut a 3-1/4" x 10" (8.3 cm
x 25 cm) vent opening in the soffit.
18.
The hood is attached to
cabinet bottom by four screws
with washers inserted through
cabinet bottom from inside of
cabinet and into hood.
• If your cabinet has a frame
around the bottom, use the
four 2-3/4" (7 cm) long screws
in parts bag.
• If your cabinet has a flush
bottom (no frame), use the four
shorter 2" (5.1 cm) long screws
in parts bag.
WARNING
Excessive Weight Hazard
Use two or more people to move
and install range hood.
Failure to do so can result in
back or other injury.
19.
Lift hood into place while
feeding wiring into wiring box.
Feed enough wire into wiring box
to easily make the connections
and tighten the strain relief.
Insert the four screws through
cabinet bottom and into hood.
Start screws into hood and
tighten securely.
20.
Connect the vent system.
Non-vented installations: Install
the grille on the soffit.
Electrical
connection
WARNING
Electrical Shock Hazard
Disconnect power before making
electrical connections.
Connect ground wire to green
ground screw in terminal box.
Failure to do so can result in
death or electrical shock.
green ground
screw
21.
Connect the white and
black wires of power supply cable
to the white and black leads in
hood with twist-on connectors.
Connect the power supply ground
wire to the green ground screw
inside hood's terminal box.
Replace terminal box cover.
22.
Reinstall light panel.
Insert light panel tabs into slots.
Push in on back of light panel and
insert the small tabs into the
locating holes in back of the
hood. Reinstall the 2 screws and
tighten securely.
filter hub
23.
Non-vented (recirculating)
installations: Install the charcoal
filters. Place filter over hub in
blower openings, push up and
turn clockwise to lock filter into
place.
24.
Install the aluminum
grease filters.
install
screw
tab