Maintenance
9
3.4 Clean the water valve
At regular basis, check the water valve and filter.
Disconnect the power to the machine.
Disconnect the water supply to the heat pump.
Disassemble the water valve (A) and check that the hole is not blocked. Check the filter.
Check the drain for condensed water (B) and the drain for cooling water (C).
④
B
C
A
fig.8038A
Clean and remove any dirt or coating if necessary.
Remount the valve.
3.5 Maintenance to be carried out by qualified service personnel
Service should be done according to the service manual. If neglected performance will decrease
and the machine can be damaged.
After 800 hours of operation or once a year, whichever comes first, contact qualified service
personnel to perform the following maintenance for e.g:
• Clean the heat pump unit inside.
• Clean condenser, evaporator and fan.
• Clean the area around the drum.
• Clean the glide surface on the RMC graphite collector.
• Clean the motor.
• Clean the component unit.