Download Print this page

Model Number Nomenclature - Johnson Controls S1-TTSCC01 Technical Manual

Zoning communicating control
Hide thumbs Also See for S1-TTSCC01:

Advertisement

885616-UTG-A-0812

MODEL NUMBER NOMENCLATURE

Touch Screen Master & Sensor
S1 - T TS C C 01 A
S1
T
TS
C
C
01
A
Zone Display
S1 - T C ZS D 01 A
S1
T
C
ZS
D
01
A
PRODUCT DATA INFORMATION
Compatible Communicating Products
Model Description
Air Conditioning
Heat Pumps
Gas Furnaces
Air Handlers
Physical Characteristics
Dimensions:
See drawing
Appearance:
Plastic, white color, textured
Electrical Characteristics/Communication
Input Volts/Amps 24VAC:
Each device in the communicating system has a four-pin con-
nector labeled A+, R, C, B-. It is recommended that the follow-
ing color code be used when wiring each device:
A+ Green = Data A+
R Red = 24VAC (Hot)
C Black = 24VAC (Com)
B- White = Data B-
Environmental Requirements
Operating Temperature/Relative Humidity:
User interface and all sensors: 32F to 104F / 0C to 40C, 95%
RH non-condensing.
Storage Temperature/Relative Humidity:
User interface: -40F to 134F /-40C to 56.7C, 95% RH non-con-
densing.
2
Source 1
Tag in a bag
Touch Screen
Communicating
Control
1st Generation
Revision A
Source 1
Tag in a bag
Communicating
Zone Sensor
With Display
1st Generation
Revision A
YORK
CZF, CZH
YZF, YZH
YPLC, YP9C
MV, AV*, AHV
Zone Panel
S1 - T C ZCB 01 A
S1
T
C
ZCB
01
A
Zone Sensor
S1 - T C ZS N 01 A
S1
T
C
ZS
N
01
A
COLEMAN
AC6, AC8
HC6, HC8
CPLC, CP9C
MV, AV*, AHV
Wiring Requirements
Power supply:
Dedicated 24VAC, 40 va, 60 Hz, via indoor equipment A+, R, C,
B- Connector. Isolated transformer, field supplied.
Wiring material:
Standard thermostat wire 18 to 24 gauge.
Feature Specifications
• Temperature set point range: 40F to 90F / 4.4C to 32.2C
• Separate heat and cool setpoints
• Programming days: 7 day
• Programming periods:
2 Periods: Day, Away
3 Periods: Day, Away, Sleep
4 Periods: Awake, Away, Return, Sleep
• Non-Programmable
• Auto changeover (may be disabled)
• Programmable fan (installer selectable)
• Humidity Sensor Offsets
• Smart Recovery (in heating and cooling)
• Copy functions: Copy period, day and zone
• Permanent memory
• Humidity display and control
• Temperature sensor offsets (indoor and outdoor)
Source 1
Tag in a bag
Communicating
Zone Control Board
1st Generation
Revision A
Source 1
Tag in a bag
Communicating
Zone Sensor
No Display
1st Generation
Revision A
LUXAIRE
AL6, AL8
HL6, HL8
LPLC, LP9C
MV, AV*, AHV
Johnson Controls Unitary Products

Advertisement

loading

This manual is also suitable for:

S1-tczcb01S1-tczsd01S1-tczsn01