4.
In the SERVICE mode, adjust CXA1839 No.6 SPC2 so
that 0 IRE ~ 100 IRE becomes almost 2.0Vp-p.
5.
In the same manner, adjust CXA1839 No.1 SBRT so
that the 0IRE level becomes 2.8Vdc.
6.
Save the data.
0 IRE
0 IRE-100IRE : 2.0Vp-p
0 IRE : 2.8Vdc
Fig. 13
100 IRE
0 V
– 41 –
•
Hue and Color Adjustment (NTSC)
1.
Enter 75% Full Field Color Bar from the RGB1 input.
2.
Connect oscilloscope to TP4003.
3.
In the SERVICE mode, adjust CXA1839 No.7 SCL2 so
that the peak level of two pulses on both sides becomes
almost equal.
4.
In the same manner, adjust CXA1839 No.0 SHUE so
that the peak level of central two pulses becomes almost
equal.
5.
Save the data.
* Adjust No.7 SCL2 to
attain same level
Fig. 14
KL-W7000A/W9000A
RM-Y980
* Adjust No.0 SHUE to