• Install the diverter plug into the filter socket.
Insert plug up into the filter socket as far as
possible and twist clockwise (to the right)
one-quarter turn until it stops.
5. Open Faucets. Turn ON the water pump and
open all sink faucets and shower head knobs.
Leave open after water stops flowing.
6. Drain Toilet. Press the toilet flush pedal and
hold until water stops flowing in the toilet.
Turn the water pump switch OFF.
7. Drain Water Heater. Turn OFF the water
heater power switch before draining the water
heater tank to avoid damage to the heating
element. Drain the water heater by removing
the plug from the base of the water heater tank,
accessible beneath the forward facing dinette
seat.
Water Heater Drain Plug
CAUTION
Hot water can escape from tank causing
injury. Operate relief valve or remove
drain plug only when the tank water is
cold.
Also, open the Pressure-Temperature Relief
valve at the top right portion of the tank to
prevent air locking in the tank while draining.
Pressure-Temperature Relief Valve
(Lift handle only when water heater is cold)
8. Connect Air Pressure. After water has
stopped draining at all faucets and drain
valves, leave faucets open and connect a
"blow-out" plug to the city water connection
(located in the water service center.) Then, use
a compressed air hose regulated to 30 psi or
less to force air through the system.
A "blow-out" plug can be purchased at any
Winnebago Industries
City Water
Connection
Blow-out
Fresh Water
Inlet
SECTION 7 –
PLUMBING
®
dealer.
Air Hose
Plug