To Retrieved Last State Error - Daikin FTXN-LV Troubleshooting Manual

Inverter split wall mounted type l-series
Table of Contents

Advertisement

1. Hold down ON TIMER CANCEL or OFF TIMER CANCEL for 5 seconds until "
flashes on the handset temperature display section.
2. Then, press the same button repeatedly. A series of error code will appear until ID buzzer produces a
long beep. The corresponding error code is indicated on the handset temperature display section.
3. ID unit buzzer will produce a long beep if the handset error code matched with unit error.
4. A short and two consecutive beeps is Not the unit error.
5. The code display will cancel itself if the button is not pressed for 1 minute.
How to Retrieved Last State Error:
1) Remove battery from remote controller.
2) Replace battery again into remote controller.
3) Press Mode & ON/OFF buttons together.
4) The " 00 " will show at temperature section.
5) Press Mode button to 5:00
6) Press Power On. Unit LED blink two times
7) ON hold fan button till screen become normal display.
TS13-01 Troubleshooting manual
ON TIMER CANCEL
OFF TIMER CANCEL
" indication
16