• Alternate CV mode selection. Default CV mode will be non-syner-
gic FCAW-SS (mode 6). Alternate settings will be non-synergic
GMAW (mode 5) and non-synergic FCAW-GS (mode 7). The left
display will show "CV" and "type" alternately at 0.5 second
intervals. The right display will show "FC.SS"(Figure B.6),
"FC.gS"(Figure B.7) or "MIG"(Figure B.8). This setting will be
stored in system memory and will be remembered between
machine power cycles. This setting will only be visible if the
process selection switch is in the CV Wire position.
FIGURE B.6
FIGURE B.4
• Selection of the remote connector for stick (SMAW) modes. The
customer can select between the 12-pin or the 14-pin connector
for the remote potentiometer input when in the "remote" switch
position for stick (SMAW) modes. The default from the factory will
be the 12-pin connector. The left display will show "Pot",
"12P"(Figure B.9) and the right display will show "Pot",
"14P"(Figure B.10). This setting is stored in system memory and
will be remembered between machine power cycles. This selec-
tion will only be visible for stick (SMAW) modes.
FIGURE B.9
FIGURE B.8
FIGURE B.6
FIGURE B.10
B-5
FIGURE B.7
FIGURE B.5
OPERATION