Call sequences

As it is not possible to program call sequences using the keypad, default call
sequences are used which depend on the mixture of monitoring centre, personal
recipient and information numbers programmed into the Vi+. The default call
sequences are as follows:
Only monitoring centre numbers programmed
When an alarm is raised, the Vi+ firstly calls alarm number 1 twice and thereafter
calls alarm numbers 2, 3 and 4 once each. If there is no answer from any of the four
numbers, the Vi+ calls alarm number 1 again, but this time four times, and then calls
the next alarm number etc. until the alarm is received. The maximum number of call
attempts is 10 therefore the call sequence used is as follows:
x2
x1
x1
Only personal recipient numbers 1-3 programmed
The following call sequence is used:
x1
x1
x1
Both monitoring centre and personal recipient numbers 1-3 programmed
The following call sequence is used:
x1
x1
x1
ConnectMe Tunstall Vi+ Installation and Programming Manual
x1
x4
x4
x4
x4
x4
x4
x2
x1
x1
x8
x4
x8
x8
x4
x4
x4
x8
29