Installer Keypad (51900/10)
Introduction
The keypad is designed to enable a trained installer to configure a home unit prior to
use. It must not be left connected to an operational unit. If unused for 5 minutes the
keypad will enter a "sleep" condition, and if left connected to a home unit warning
tones will be sounded until it is disconnected. Attachment points are provided to
enable the keypad to be carried on a neck cord/belt clip. The slot on the rear of the
Keypad can be used to hold an ID card or this quick reference card.
Connecting the Keypad
Connect this
the keypad
Programming
Any parameter value can be set by using the keypad, to program a parameter enter
the following key sequence:
AAA
BBBB
AAA is the parameter number and BBBB is the value to be programmed
e.g. * 2 * 995* would program the units ID to 995.
Enquiry
It is possible to enquire what value is stored in any parameter, to do this enter the
following key sequence:
Parameter number
This will displays current value of the specified parameter
e.g.
might show *2*995EEEEEEEEEEEEE
Note that "E" denotes an "empty" digit. This is shown when reading a parameter but
will be added automatically when programming new values.
ConnectMe Tunstall Vi+ Installation and Programming Manual
end to
(max 16 digits)
Connect this end to
the Aux socket on the
Vi+
26