Dometic DM50D Installation And Operating Manual

Dometic DM50D Installation And Operating Manual

Drawer minibar
Hide thumbs Also See for DM50D:

Advertisement

Drawer Minibar
EN
Installation and Operating Manual . . . 3
DM50

Advertisement

Table of Contents
loading

Summary of Contents for Dometic DM50D

  • Page 1 Drawer Minibar Installation and Operating Manual . . . 3 DM50...
  • Page 3: Table Of Contents

    DM50 Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is passed on to another person, this operating manual must be handed over to the user along with it. The manufacturer cannot be held liable for damage resulting from improper usage or incorrect operation.
  • Page 4: Explanation Of Symbols

    Explanation of symbols DM50 Explanation of symbols WARNING! Safety instruction: Failure to observe this instruction can cause fatal or serious injury. CAUTION! Safety instruction: Failure to observe this instruction can lead to injury. NOTICE! Failure to observe this instruction can cause material damage and impair the function of the product.
  • Page 5 DM50 Safety instructions  Cleaning and user maintenance must not be carried out by chil- dren without supervision.  Always keep and use the device out of the reach of children under the age of 8 years.  Children must be supervised to ensure that they do not play with the device.
  • Page 6: Scope Of Delivery

     Protect the device and the cable against heat and moisture. Scope of delivery The following main alternatives are obtainable:  Minibar DM50D with door panel, without lock  Minibar DM50D with door panel, with lock  Minibar DM50F without door panel, without lock ...
  • Page 7: Proper Use

    Proper use Proper use The Dometic Minibars DM50D and DM50F are designed for use inside a piece of furniture and are suitable for cooling beverages and food. The device is designed for use with a 230 V AC mains supply.
  • Page 8 Technical description DM50 Description of the device Front panel Item Description Lock (optional) Handle (DM50D only) Door panel (DM50D only)
  • Page 9 DM50 Technical description Rear side Item Description Mains adaptor 12 Vg socket Cooling unit cover Ventillation openings Drip tray...
  • Page 10 Technical description DM50 Control panel (inside the device) Item Description Lamp Error LED Status LED Setting button...
  • Page 11 DM50 Technical description Main drawer Item Description Wide divider Separator Small divider Bottle finger...
  • Page 12 Technical description DM50 Mini drawer Item Description Rotatable divider Miniature bottle holder Dimensions 91,2...
  • Page 13: Installation

    Observe the following:  The cut-out dimensions H x W x D are: – DM50D: 428 x 570 x 485 mm – DM50F: 428 x 570 x (485 + d) mm d is the thickness of the hotel‘s own decor ...
  • Page 14 Installation DM50 ≥ 150 cm² ≥ 35 cm² ≥ 150 cm² ≥ 150 cm² ≥ 35 cm² ≥ 15...
  • Page 15 DM50 Installation Pressing out the ventilation opening ➤ Produce a ventilation opening of 30 x 300 mm in the bottom of the furniture into which you place the minibar. Measure the distance of 470 mm from the minibar‘s door front excluding any own decor.
  • Page 16 Installation DM50 Mounting the minibar into a piece of furniture Item Description Screw ø4 x 45 mm Plug Furniture Ventilation opening Filter Screw ø3 x 12 mm ➤ Fasten the minibar with the four screws ø4 x 45 mm (1). ➤...
  • Page 17: Operation

    DM50 Operation Connecting the minibar electrically ➤ Plug the 230 V connection cable into the AC voltage socket and connect it to the 230 V AC mains supply. ✓ The status LED lights up. ✓ The minibar starts cooling the interior. Mounting hotel's own door decor (DM50F only) The hotel's own door decor has to comply with the following requirements: ...
  • Page 18 Operation DM50 Using the minibar The minibar starts cooling when connected to power. During normal operation the Status LED is glowing. If an error occurs the Error LED is blinking (see chapter “Troubleshooting” on page 19). The minibar is set by default to a cooling temperature of 7 °C at an ambient temperature of 25 °C.
  • Page 19: Troubleshooting

    DM50 Troubleshooting Troubleshooting Fault Possible cause Suggested remedy Device does not No voltage present in Try using another plug socket. function, Status LED the AC voltage socket. does not glow. The mains adapter is This can only be repaired by an defective.
  • Page 20: Cleaning And Maintenance

    Cleaning and maintenance DM50 Cleaning and maintenance WARNING! Always disconnect the device from the mains before you clean and service it. NOTICE! Risk of damage  Never clean the cooler under running water or in dish water.  Do not use abrasive cleaning agents or hard objects during cleaning as these can damage the cooler.
  • Page 21: Guarantee

    DM50 Guarantee Guarantee The statutory warranty period applies. If the product is defective, please contact your retailer or the manufacturer's branch in your country (see the back of the instruction manual for the addresses). For repair and guarantee processing, please include the following docu- ments when you send in the device: ...
  • Page 22: Technical Data

    Technical data DM50 Technical data DM50D DM50F Voltage: 100 – 240 Vw, 50 Hz Cooling capacity: max. 21 °C under ambient temperature (adjustable in three steps: 5 °C, 7 °C, 12 °C) Category: 2 (Cellar) Gross capacity: 50 l Capacity:...
  • Page 24 GERMANY Dometic WAECO International GmbH Hollefeldstraße 63 · D-48282 Emsdetten  +49 (0) 2572 879-195 ·  +49 (0) 2572 879-322 Mail: info@dometic-waeco.de · Internet: www.dometic-waeco.de AUSTRALIA ITALY TAIWAN Dometic Australia Pty. Ltd. Dometic Italy S.r.l. WAECO Impex Ltd. 1 John Duncan Court...

This manual is also suitable for:

Dm50fDm50