Cycle Times/24-Hour Ice Production/Refrigerant Pressure Charts - Manitowoc RNS012 Technician's Handbook

Nugget ice machines
Table of Contents

Advertisement

Cycle Times/24-Hour Ice Production/
Refrigerant Pressure Charts
These charts are used as guidelines to verify correct
ice machine operation.
Accurate collection of data is essential to obtain the
correct diagnosis.
Refer to "Refrigeration System Diagnostics" for the
data that must be collected. This list includes:
before beginning service, ice production check,
installation/visual inspection, water system
checklist, safeguards, discharge and suction
pressure analysis.
Ice production checks that are within 10% of the
chart are considered normal. This is due to
variances in water and air temperature. Actual
temperatures will seldom match the chart exactly.
Zero out manifold gauge set before obtaining
pressure readings to avoid misdiagnosis.
Discharge and suction pressure are highest at the
beginning of the cycle. Allow system to stabilize,
then verify the pressures are within the range
indicated.
All pressure readings must be obtained at the ice
machine head section. Lineset length will affect
pressures at the condensing unit.
Water temperature will affect suction and
discharge pressure - 50° water temperature will
result in pressures on the lower end of the ranges
specified. 90° water temperatures will result in
pressures on the upper end of the ranges
specified.
Part Number STH044 10/13