PIAGGIO 633929(IT) Service Station Manual page 199

Table of Contents

Advertisement

MP3 125
Suspensions
The hand-held computer indicates the outcome of
the stop search operation:
POSSIBLE LIMIT STOP VALUES. TO EXIT,
PRESS A KEY AND TURN OFF AND ON. SE-
LECT PARAMETERS TO ADJUST AT 12°.
Check the geared motor if the hand-held computer
does not indicate this.
Select the PARAMETERS option from the main
menu
The hand-held computer displays the option: REL-
ATIVE POTENTIOMETER ANGLE
This function is active coming from the LOWER
STOP SEARCH procedure.
NOTE: a slight oscillation of the angle value be-
tween 0.00° and 0.50° is considered normal
Remove the protection cap of the geared motor set
screw
Use a plain slot screwdriver to turn the set screw
anticlockwise until replicating the 12° condition on
the hand-held computer
RELATIVE POTENTIOMETER ANGLE 12° (a
slight value oscillation is considered normal)
Refit the protection cap
SUSP - 27